VISTA-10SE Installation and Setup Guide
10-2
Panic Keys
There are three individual panic keys and/or, on some keypads, panic key pairs. If programmed, they can be used to manually initiate
alarms and send a report to the central station.
Each key (or key pair) can be individually programmed for 24-hour Silent, Audible, Personal, or Fire Emergency responses. The panic
function is activated when both keys of the appropriate key pair are pressed at the same time, or the appropriate lettered key is pressed
for at least 2 seconds.
OFF AWAY STAY
INSTANT
CODE CHIME
MAX TEST BYPASS
READY
PANIC
1
2
3
6
5
4
897
0
*
#
ARMED
READY
A
B
C
D
Shown above is a typical 2-line alpha keypad
with individual Panic keys (shown lettered).
The panic functions are identified by the
system as follows:
Keys Displayed as Zone
[A], or [1] & [
✱
] 95
[B], or [
✱
] & [#] 7
[C], or [3] & [#] 96
Notes:
• Keys [A], [B], [C] are not on all keypads.
• Key [D], if present, is not active here.
Important:
For the Silent Panic functions to be of practical value, the system must be connected to a central station.
4285/4286 VIP Module (if used)
Refer to the separate instructions supplied with the VIP Module for information concerning its operating procedures.
Relay Outputs
(if used)
If relay outputs are used, two keypad entries available to the user are included among the system operation choices (34 and 35) that
may be programmed (see
SECTION 6: Output Device Programming
). They can manually activate or deactivate the relay(s) for starting
or stopping some action, such as turning lights on or off, etc.
These keypad entries are:
Security Code + [#] + [7]
and
Security Code + [#] + [8]
NOTE:
The keypad entry that is used to Start/Stop the action, cannot also be used to Stop/Start it. The opposite action must either be
performed by the other keypad entry or by some other event or operation offered in
SECTION 6: Output Device Programming
.
Exit Error Alarm Displays
(if programmed)
2-Line Alpha Display
Fixed-Word Disp
lay
Meaning
CANCELED ALARM
CA
A display of
CANCELED ALARM
or
CA
and a zone indication appears if an
exit or interior zone contained a fault during closing at the time the exit delay
ended (e.g., exit door left open),
and the system was disarmed during the
subsequent entry delay time.
The alarm sounder and keypad sound
continuously, but stop when the system is disarmed. No message will be
transmitted to the central station.
EXIT ALARM EA
A display of
EXIT ALARM
or
EA
and a zone indication will appear if an exit
or interior zone contained a fault during closing at the time the exit delay
ended,
and the system was NOT disarmed during the subsequent entry delay
time.
The alarm sounder and keypad sound continuously until the system is
disarmed (or timeout occurs). An "exit alarm" message is sent to the central
station.
The
EXIT ALARM
display, etc. also result if an alarm from an exit or interior
zone occurs within two minutes after the end of an exit delay.
NOTE:
To clear display in either of the two above cases, use a second OFF sequence (
CODE
plus
OFF
[1] key) to clear the display.