4-1
SECTION 4
Data Field Programming
•••••••••••••••••••••••••••••••••••••••••••••••••
About Data Field Programming
The following pages list this controls data fields in numerical order. Field numbers are listed in the left column, followed
by a Title and Data Entries column, which lists the valid entries for each field. Experienced installers can simply follow
this column when programming the data fields. The Explanation column provides explanatory information and special
notes where applicable.
Use the blank programming form to record the data for this installation.
Programming Data Fields
Data field programming involves making the appropriate entries for each of the data fields.
Start Data Field programming by entering the Installer code + 8 + 0.
System Setup Fields
20
27
FIELD TITLE and DATA ENTRIES EXPLANATION
20
Installer Code
Enter 4 digits, 0 - 9
The Installer Code is used to assign the 4-digit Master
Security Code. See "Master Code" in SECTION 10: System
Operation for procedure.
21
Quick Arm Enable
0 = do not allow quick arm
1 = allow quick arm
If enabled, a user code is not needed to arm the system.
Instead, users can press the [#] followed by an arming key
to arm the system.
However, the user code is always needed to disarm the
system.
22
RF Jam Option
0 = if no receiver is being used
2 = 5800 system receiver; no jam detection
4 = 5800 system receiver with jam detection
This option is enabled if a wireless receiver is used.
If enabled, a report is sent if the system detects an RF
jamming signal.
23
Forced Bypass
0 = no forced bypass
1 = automatically bypass all faulted zones
All zones bypassed by this function will be displayed after
the bypass is initiated.
UL installations must be set to 0 (no forced bypass)
24
RF House ID Code
00 = disable all wireless keypad usage
01-31 = House ID
The House ID identifies receivers and wireless keypads. If
a 5827 or 5827BD Wireless keypad or 5804BD Transmitter
is being used, a House ID code
must
be entered, and the
keypad should be set to the same House ID.
25
Output Relay Module
0 = if no relay module will be used
3 = if a relay module is used
Enabled if a 4204 Relay Module (containing 4 Form C
relays) is used in the system.
26
Access Code for VIP (Phone) Module
1-9 = first digit of access code
or # = second digit of access code
(enter # +11 for
, or # +12 for #)
You need to assign a 2-digit access code for the 4285/4286
VIP (Phone) Module, if used.
Example: If desired access code is 7
, 7 is the first entry,
and [#] + 11 (for
) is the second entry.
NOTE:
A 0 in either digit disables the phone module.