VISTA-10SE Installation and Setup Guide
6–2
STOP (STP)
The "STOP" programming determines when and under what conditions the relay will be de-activated. The following
options are available:
1.
RESTORE ZONE LIST (ZL)
. If a "ZONE LIST" is used as the “Stop” event, the relay will de-activate when
all
the
zones in that list restore from a previous fault, trouble, or alarm condition. This will occur regardless of what is
programmed to "START" the relay; therefore, a "RESTORE ZONE LIST" would normally only be used when a
"ZONE LIST" is used to start the relay.
2.
ZONE TYPE/SYSTEM OPERATION (ZT).
Instead of using a "RESTORE ZONE LIST," a specific zone (response)
type or system operation action can be selected to de-activate the relay.
If a specific "ZONE TYPE" is chosen,
any zone of that response type that restores from a previous alarm, trouble, or
fault condition will cause the relay to de-activate.
If a "SYSTEM OPERATION" is chosen, that operation will cause the relay to de-activate. The different choices for
"ZONE TYPE" and "SYSTEM OPERATION" are listed in “Programming Output Devices” later in this section, and in
the Programming Form.
If relay outputs are used, two keypad entries available to the user are included among the system
operation choices (34 and 35) that may be programmed. They can manually activate or de-activate
the relay(s) for starting or stopping some action, such as turning lights on or off, etc.
These entries are:
Security Code + [#] + [7]
and
Security Code + [#] + [8]
NOTE
:
Whichever entry is used to start/stop the action cannot also be used to stop/start it. The
opposite action must either be performed by the other keypad entry or by some other event or
operation defined in the programming section.
If a relay is energized before a 4-wire smoke detector is reset, the relay will be stopped by the
interruption of Aux.
Power that resets the smoke detector. If this is not desired, the power to the
relay unit should be supplied from another 12VDC power source (e.g., the same source that is
powering external equipment through the relay contacts).
Programming Output Devices
1.
With at least one 2-line alpha keypad (6139) connected to the keypad terminals on the control, power-up the system
temporarily. If you previously connected the AC transformer to the control panel, you need only plug in the
transformer (to 120VAC outlet) to power-up the system.
2. Enter the programming mode by keying the following on the alpha keypad:
INSTALLER Code (4 1 1 1) + [8] + [0].
Field
✱
25 OUTPUT RELAY MODULE must have been programmed for a 4204 module (enter “3”).
3.
Press
✱
80.
Note that this is an Interactive Menu Programming mode. It is used to program all output relays used
in the system (4204 Relay modules). Refer to the Programming Worksheet in the separate PROGRAMMING FORM
for
✱
80 Interactive Mode.