Section 5 - Zone Programming
53
PROMPT VALID ENTRIES EXPLANATION
10 INPUT S/N L
A022-4064 ?
Loop Number Entry
[
]
to accept and continue
NOTE:
If you use the [C] key to copy the previously enrolled serial
number, the cursor moves to the Loop column (L) with the serial
number displayed, and displays a question mark
?
for the loop
number.
Enter the loop number and press [
]. Refer to the graphic of
wireless devices on a following page in this section for the correct
number of loops and loop identification numbers.
The system then checks for a duplicate serial/loop number
combination.
If a
duplicate
serial/loop number combination is found, the keypad
emits a single long beep, and displays the serial number along with
a
?
for the loop number, allowing you to reenter the correct loop
number.
XMIT
TO
CONFIRM
PRESS
TO SKIP
Confirmation Option
[
]
to continue
This prompt appears only if you answered
Yes
to the first prompt in
this section.
The system enters a confirmation mode so that the operation of the
actual programmed input can be confirmed. Activate the loop input
or button that corresponds to this zone.
We recommend that you confirm the programming of every
transmitter before proceeding to the next zone.
Keyd A022-4063
1
Rcvd A022-4064 1
No Match
If the serial/loop number combination transmitted
does not match
the serial number entered, a display similar to the one at left
appears. If the loop number does not match, it is also displayed.
If so, activate the transmitter's loop input or button one or more
times. If a match is still not obtained (i.e., summary display does
not appear), press the [#] key twice and enter the correct loop
input or, if correct, press the [#] key again and then enter the
correct serial number.
Zn ZT RC In: L
10 03 10 RF:
1s
Summary Display
[
]
to accept zone summary
and continue
If the
serial number transmitted matches
the serial number
entered, the keypad beeps 3 times and a summary display appears,
showing that zone's programming. Note that an s after the loop
number indicates that a transmitters serial number has been
enrolled.
PROGRAM ALPHA?
0 = NO 1 = YES 0
Alpha Descriptors
0 = no
1 = yes
[
]
to continue
If you want to program descriptors for zones now, enter
1
(Yes) and
refer to
SECTION 8: Alpha Descriptor Programming
for
available descriptors.
ENTER ZN NUM.
(00 = QUIT) 11
Next Zone Number
00 = quit
If you entered
0
(No) above, the system returns you to the
ENTER ZN NUM.
prompt for the next zone.
When all zones have been programmed, enter
00
to quit
.
NOTE:
Following the successful enrollment of each wireless device, remove
ONE
of the serial number labels from the
device and affix it in the appropriate column on the ENROLLED TRANSMITTERS worksheet of the Programming
Form. Then enter the other information (zone number, zone type, loop number, etc.) relevant to that device. This
information will be useful if any troubleshooting is needed later on. The installer may want to consider leaving this
worksheet at the site (in the panel cabinet).
Testing the Zones
When you have finished programming all zones, test each zone using the systems TEST mode.
Do not use the
Transmitter ID Sniffer Mode for checking wireless transmitting devices
, as it will only check for transmission of
one zone on a particular transmitter, NOT the zones assigned to each additional loop.