VISTA-10SE Installation and Setup Guide
4-6
If an exit or interior zone contains a fault as the exit delay ends
, the local bell and keypad sound
continuously.
a) If the subscriber then disarms the system before the ensuing ENTRY delay ends, no message is
transmitted to the central station, but a zone indication and "Canceled Alarm" or "CA" is displayed on
the keypad.
b) If the system is not disarmed before that entry delay ends, a special message indicating Exit Alarm is
sent to the central station and a zone indication and "Exit Alarm" or "EA" is displayed on the keypad.
For expanded or 4+2 reporting, a 2nd digit is sent, and is the same as the 2nd digit of the zone Alarm
Report code programmed in field
✱
56.
For Contact ID
®
reporting, Event code 374 and the zone number is sent.
There is no restore message for an Exit Alarm report.
FIELD TITLE and DATA ENTRIES EXPLANATION
✱
66
Away/Stay Close Report Code
0 = no report
For both digits: 1-9, A-F (Refer to table on
previous page
for method of programming
report codes.)
This is a 2-digit entry field.
This option allows for programming of AWAY and STAY
reports.
✱
67
RF Xmtr LOW BAT Report Code
0 = no report
For both digits: 1-9, A-F (Refer to table on
previous page
for method of programming
report codes.)
This is a 2-digit entry field.
This is sent in the event that a wireless transmitter low
battery condition exists.
✱
68
Cancel Report Code
0 = no report
For both digits: 1-9, A-F (Refer to table on
previous page
for method of programming
report codes.)
This is a 2-digit entry field.
This is sent upon disarming of the system after an alarm
condition was reported.
RESTORE REPORT CODES (
✱
70 –
✱
75)
✱
70
Alarm Restore Report Code
0 = no report
For both digits: 1-9, A-F (Refer to table on
previous page
for method of programming
report codes.)
This is a 2-digit entry field.
This is sent upon disarming of the system after an alarm
condition was reported.
✱
71
Trouble Restore Report Code
0 = no report
For both digits: 1-9, A-F (Refer to table on
previous page
for method of programming
report codes.)
This is a 2-digit entry field.
This is sent when a trouble in a zone is restored.
✱
72
Bypass Restore Report Code
0 = no report
For both digits: 1-9, A-F (Refer to table on
previous page
for method of programming
report codes.)
This is a 2-digit entry field.
This is sent when a zone that has been bypassed is
unbypassed.
✱
73
AC Restore Report Code
0 = no report
For both digits: 1-9, A-F (Refer to table on
previous page
for method of programming
report codes.)
This is a 2-digit entry field.
This is sent when AC power has been restored after an AC
power outage.
Komentarze do niniejszej Instrukcji