VISTA-15/VISTA-15CN Installation and Setup Guide1–2Security Codes Supported• One Installer code for entire system (user 1)•One Master code for entire
VISTA-15/VISTA-15CN Installation and Setup Guide20–2BizComp Intellimodem 2400Hayes Optima 336 ExternalHayes Smartmodem Optima 2400Hayes Optima 2400 Fa
21–1SECTION 21System Communication•••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Panel Communication with Central Station♦Report Cod
VISTA-15/VISTA-15CN Installation and Setup Guide21–2The following table describes each format in greater detail.FORMAT TYPE DESCRIPTION3+1 and 4+1Stan
Section 21 - System Communication21–3ADEMCO Contact ID Reporting takes the following format:CCCC Q EEE ZZZwhere:CCCC = Customer (subscriber) IDQ = Eve
VISTA-15/VISTA-15CN Installation and Setup Guide21–4
22–1SECTION 22System Operation••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Security Codes♦Keypad Functions♦Relay/Powerline Carrie
VISTA-15/VISTA-15CN Installation and Setup Guide22–2• If a Secondary User code is inadvertently repeated for different users, the lower usernumber tak
Section 22 - System Operation22–3If you armed the system using the [C] (NIGHT-STAY) key, your only option is to use the[A] (AWAY) key to increase the
VISTA-15/VISTA-15CN Installation and Setup Guide22–4Relay/Powerline Carrier Device ActivationIf relay outputs (via a 4204 or 4229) or Powerline Carrie
Section 22 - System Operation22–5NOTE: It is not possible to arm the system as long as one of the above conditions exist(unless these zone(s) are bypa
Section 1 - Introduction1–3Optional VIP ModuleThe VISTA-15/VISTA-15CN supports the ADEMCO 4285/4286 VIP Module (refer toSection 8: 4285/4286 VIP Modul
VISTA-15/VISTA-15CN Installation and Setup Guide22–6Setting the Real-Time ClockGeneral InformationThis system provides a real-time clock that must be
23–1SECTION 23Testing the System••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Test Procedure•••••••••••••••••••••••••••••••••••••
VISTA-15/VISTA-15CN Installation and Setup Guide23–2Press [Installer code] + [#] + [3] on the keypad. This initiates a procedure to verifythat all tr
24–1SECTION 24Troubleshooting Guide••••••••••••••••••••••••••••••••••••••••••••••••••SYSTEM (including Wireless)SYMPTOM POSSIBLE CAUSE REMEDY1. Transm
VISTA-15/VISTA-15CN Installation and Setup Guide24–2SYSTEM (including Wireless - cont'd)SYMPTOMPOSSIBLE CAUSE REMEDY6. Nuisance or phantomalarm.6
24–3CONTACTING TECHNICAL SUPPORTPLEASE, before you call Technical Support, be sure you:• READ THE INSTRUCTIONS!• Check all wiring connections.• Determ
VISTA-15/VISTA-15CN Installation and Setup Guide24–4NOTES
25–1SECTION 25Specifications & Accessories••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Specifications♦Accessories••••••••••••
VISTA-15/VISTA-15CN Installation and Setup Guide25–26128 REMOTE KEYPAD1. Physical: 5-3/4” W x 4-3/4” H x 1” D (146mm x 121mm x 25mm)2. Electrical:Volt
Section 25 Specifications & Accessories25–34229 WIRED EXPANSION/RELAY MODULE1. Physical: 6-1/2” W x 4-1/4” H x 1-1/4” D (169mm x 108mm x 32mm)2.
VISTA-15/VISTA-15CN Installation and Setup Guide1–4Chime/Chime by ZoneChime, when on, normally sounds when any entry/exit or perimeter zone is faulted
VISTA-15/VISTA-15CN Installation and Setup Guide25–4ADEMCO 71340-watt, 8-ohm, indoor/outdoor speaker.System SensorPA400B (beige)PA400R (red)Indoor pie
A–1APPENDIX A5800 RF System Wireless Transmitters••••••••••••••••••••••••••••••••••••••••••••••••••Transmitter Input Loop Identification5800 Series Tr
VISTA-15/VISTA-15CN Installation and Setup GuideA–2
B-1APPENDIX BRegulatory Agency Statements••••••••••••••••••••••••••••••••••••••••••••••••••UL NOTICE: This is a “Grade A” residential system.FEDERAL C
VISTA-15/VISTA-15CN Installation and Setup GuideB-2California State Fire Marshal (CSFM) 24-Hour Battery Back-Up RequirementsThe California State Fire
C-1APPENDIX CWarnings and Limitations••••••••••••••••••••••••••••••••••••••••••••••••••WARNINGTHE LIMITATIONS OF THIS ALARM SYSTEMWhile this System is
VISTA-15/VISTA-15CN Installation and Setup GuideC-2ADEMCO LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and i
Index-1Index••••••••••••••••••••••••••••••••••••••••••••••••••1321/1321CN ...1–2, 1–4, 2–5, 7–3, 12–124 Hour Monitor...
VISTA-15/VISTA-15CN Installation and Setup GuideIndex-2Cross Zoning ...18–2CSFM Requirements...
IndexIndex-3Programming...1–4, 13–1Programming Hardwired Zones...4–4Programming Mo
2–1SECTION 2Installing the Control••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Mounting the Cabinet♦Installing the Lock♦Mounting
VISTA-15/VISTA-15CN Installation and Setup GuideIndex-4
AUX. POWEROUTPUT10.5-13.8VDC600mA MAX.(500mA MAX.FOR ULINSTALLATIONS)INTERRUPTSFOR 4-WIREFIRE ALARMRESET. ALLCIRCUITS AREPOWERLIMITED.NOTE:KEYPAD(S) C
165 Eileen Way, Syosset, New York 11791Copyright © 2000 PITTWAY CORPORATION¬.9ElK3892V1 4/00
VISTA-15/VISTA-15CN Installation and Setup Guide2–2Before installing the cabinet's contents, remove the metal cabinet knockouts required for wiri
Section 2 - Installing the Control2–3Mounting Control and RF Receiver Circuit Boards Together in the CabinetTo mount the control and RF receiver board
VISTA-15/VISTA-15CN Installation and Setup Guide2–4Standard Phone Line ConnectionsThe wiring connections shown here are not applicable if the 4285/428
Section 2 - Installing the Control2–5Wiring the AC Transformer1321/1321CN TransformerWire the 1321/1321CN Transformer to terminals 1 and 2 on the cont
VISTA-15/VISTA-15CN Installation and Setup Guide2–6Installing the Backup BatteryIf necessary, refer to Section 12: Final Power-Up for information rega
3–1SECTION 3Installing Remote Keypads••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Keypads That May Be Used♦Wiring to the Keypads♦
VISTA-15/VISTA-15CN Installation & Setup Guideii
VISTA-15/VISTA-15CN Installation and Setup Guide3–2The length of all wire runs must not exceed 1500 feet (457m) when unshielded quad conductorcable is
Section 3 - Installing Remote Keypads3–3Make connections directly to the screw terminals as shown in Figure 7. Make no connection to thekeypad blue wi
VISTA-15/VISTA-15CN Installation and Setup Guide3–4
4–1SECTION 4Basic Hardwired Zones 1–6••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Installing the Hardwired Zones♦Programming Hard
VISTA-15/VISTA-15CN Installation and Setup Guide4–2Wiring 2-Wire Smoke Detectors to Zone 11. Connect 2-wire smoke detectors across zone 1 terminals 8
Section 4 - Basic Hardwired Zones 1-64–3Remove 2000 ohm EOL resistor if connected across the selected zone terminals. You mustconnect the EOL resistor
VISTA-15/VISTA-15CN Installation and Setup Guide4–4Programming Hardwired ZonesEach zone must be programmed into the system using the ✱56 Zone Programm
5–1SECTION 5Wired Zone Expansion••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Installing Zone Expansion Units♦Connections and Setu
VISTA-15/VISTA-15CN Installation and Setup Guide5–24219GRNBLK(–) GROUNDRED(+) 12VDCYEL4321ZONESABCDFGHTAMPER JUMPERPOSITION IN CABINET(NOT TAMPER PROT
Section 5 - Wired Zone Expansion5–3Programming Wired Expansion ZonesEach zone must be programmed into the system using the ✱56 Zone Programming Mode o
iiiRECOMMENDATIONS FOR PROPER PROTECTIONThe Following Recommendations for the location of Fire and Burglary DetectionDevices Help Provide Proper Cover
VISTA-15/VISTA-15CN Installation and Setup Guide5–4
6–1SECTION 6Wireless Expansion (5800 System)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ About Wireless Expansion♦ Installing th
VISTA-15/VISTA-15CN Installation and Setup Guide6–2Installing the 5881/5882 ReceiverRF System Installation AdvisoriesFollow the guidelines below when
Section 6 - Wireless Expansion6–3Installing the 5800TM ModuleInstallation of this module is necessary only if you are using one or more 5827BD wireles
VISTA-15/VISTA-15CN Installation and Setup Guide6–4For button transmitters (RF “keys”), such as the 5801, 5804, and 5804BD, you must assign aunique zo
Section 6 - Wireless Expansion6–5Transmitter Battery LifeDo not install batteries in wireless transmitters until you are ready to enroll the transmitt
VISTA-15/VISTA-15CN Installation and Setup Guide6–65800 Series Transmitters TableAlso refer to Appendix A for transmitter input loops/button locations
Section 6 - Wireless Expansion6–7Installing 5800 Series TransmittersTo be sure reception of the transmitter's signal at the proposed mounting loc
VISTA-15/VISTA-15CN Installation and Setup Guide6–8
7–1SECTION 7Relay Outputs & Powerline Carrier Devices••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Relays and Powerline
ivTable of Contents••••••••••••••••••••••••••••••••••••••••••••••••••Conventions Used In This Manual...
VISTA-15/VISTA-15CN Installation and Setup Guide7–22. Set the 4204/4229's DIP switch for a device address of 1 (switch 2 in the OFF position ands
Section 7 - Relay Outputs & Powerline Carrier Devices7–3SWITCH 4204 ADDRESS SETTINGSPOSITION ("—" means "OFF")0 1 2 3 4 5 6 7
VISTA-15/VISTA-15CN Installation and Setup Guide7–4Wiring ConnectionsTo wire the Powerline Carrier device to the control panel, perform the following
8–1SECTION 84285 & 4286 VIP Module••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About the 4285 & 4286 VIP Module♦Installin
VISTA-15/VISTA-15CN Installation and Setup Guide8–2If you are also using an Audio Alarm Verification (AAV) unit, refer to Section 11: Audio AlarmVerif
Section 8 - 4285/4286 VIP Module8–34285/4286 VIP MODULE WIRING NOTES:• Wire the phone module exactly as shown, using a direct-connect cord and RJ31X
VISTA-15/VISTA-15CN Installation and Setup Guide8–4Programming the 4285/4286 VIP ModuleYou must program the system for use with the 4285 or 4286 VIP M
9–1SECTION 9External Sounders••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Compatible Sounders♦NFPA Requirements♦Sounder Connectio
VISTA-15/VISTA-15CN Installation and Setup Guide9–2Sounder Connections and PowerThe VISTA-15/VISTA-15CN provides a 12VDC output, which can power exter
10–1SECTION 10Long Range Radio••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Long Range Radio♦Wiring Connections♦Dynamic Sign
Table of ContentsvSECTION 10. Long Range Radio ...
VISTA-15/VISTA-15CN Installation and Setup Guide10–2Dynamic Signaling FeatureThis VISTA-15/VISTA-15CN control panel features Dynamic Signaling Delay (
11–1SECTION 11Audio Alarm Verification (AAV) Unit••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Audio Alarm Verification♦Wiri
VISTA-15/VISTA-15CN Installation and Setup Guide11–2CONTROL/DIALER HEADERNOTE:REFER TO AAV MODULE INSTRUCTIONS FOR CONNECTIONS TO AUDIO SPEAKERS AND M
12–1SECTION 12Final Power-Up••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Earth Ground Connections♦AC Power-Up♦Connecting the Back
VISTA-15/VISTA-15CN Installation and Setup Guide12–2Calculating the Battery Size NeededDetermine the total device current draw after filling in the Au
13–1SECTION 13Mechanics of Programming••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Programming♦Entering Program Mode♦Progra
VISTA-15/VISTA-15CN Installation and Setup Guide13–2Entering Program ModeYou may use one of the following methods:a) Press the [✱] and [#] keys at the
Section 13 - Mechanics of Programming13–3Loading Factory DefaultsTo load the factory defaults, enter the Programming mode, press ✱97, then exit thePro
VISTA-15/VISTA-15CN Installation and Setup Guide13–4
14–1SECTION 14Zone Response Type Definitions••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Zone Type Definitions•••••••••••••••••••
VISTA-15/VISTA-15CN Installation & Setup GuideviSECTION 22. System Operation ...
VISTA-15/VISTA-15CN Installation and Setup Guide14–2Type 04Interior FollowerThis zone type gives a delayed alarm (using the programmedentry/exit time)
Section 14 - Zone Response Type Definitions14–3Type 10Interior w/DelayThis zone type gives Entry Delay (using the programmed entrytime), if tripped wh
VISTA-15/VISTA-15CN Installation and Setup Guide14–4
15–1SECTION 15Data Field Descriptions••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Descriptions of System Data Fields••••••••••••
VISTA-15/VISTA-15CN Installation and Setup Guide15–2✱25 WIRED ZONE EXPANSION 0 0 = no expander module connected1 = 4219 connected2 = 4229 connected
Section 15 - Data Field Descriptions15–3✱30 HARDWIRE SHORT DETECTION 0 0 = disable; 1 = enableWhen enabled and a short occurs in any hardwired burg
VISTA-15/VISTA-15CN Installation and Setup Guide15–4✱36 ENTRY DELAY 2 2 0 = 30-second delay 4 = 120-second delay1 = 45-second delay 5 = 180-second
Section 15 - Data Field Descriptions15–5✱43 PRIMARY SUBS ACCOUNT NO. 15 | 15 | 15 | 15 See box at left.✱44 SECONDARY SUBS ACCOUNT NO. |
VISTA-15/VISTA-15CN Installation and Setup Guide15–6Pager Report FormatEntries 6 through 9 sends a report to a pager, using the following format:The P
Section 15 - Data Field Descriptions15–7✱52 CANCEL VERIFY 1 0 = no1 = yesWhen enabled (1 = yes), this feature causes a message of CANCELEDALARM to
viiList of Figures••••••••••••••••••••••••••••••••••••••••••••••••••Figure 1. Installing the Cabinet Lock...
VISTA-15/VISTA-15CN Installation and Setup Guide15–8SYSTEM STATUSREPORT CODES(✱59–✱68)✱59 EXIT ERROR REPORT CODE (See previous page) 0 If the syste
Section 15 - Data Field Descriptions15–9✱66 ARM AWAY/STAY REPORT CODE 0 | 0 AWAY/STAYThis option allows for independent programming of AWAY and
VISTA-15/VISTA-15CN Installation and Setup Guide15–10✱78 DAYLIGHT SAVING TIME START/END WEEKEND 1 | 5 0 = disabled 4 = fourth1 = first 5 = las
Section 15 - Data Field Descriptions15–11✱81 ZONE LISTS FOR OUTPUT DEVICESInteractive Menu mode applicable if ✱25 is programmed for a 4204 or 4229,or
VISTA-15/VISTA-15CN Installation and Setup Guide15–12✱88 PAGER CHARACTERSWhen programmed in field ✱47, reports are sent to the pager depending uponthe
Section 15 - Data Field Descriptions15–13✱90 EVENT LOGGING 3 0 = no event logging1 = log Alarm/Alarm Restore2 = log Trouble/Trouble Restore4 = lo
VISTA-15/VISTA-15CN Installation and Setup Guide15–14✱93 SWINGER SUPPRESSION 0 0 = Unlimited, 1-15 = Number of alarms (1-9; # +10 = 10; # +11 =
16–1SECTION 16Zone Programming(✱56/✱58 Menu Mode)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Zone Programming♦✱56 Zone Pro
VISTA-15/VISTA-15CN Installation and Setup Guide16–2 Zone Number10 Zone TypePerimeter 03Zone Type Zone Type (ZT): Enter the Zone Type response (or ch
Section 16 - Zone Programming16–310 INPUT S/N: L A022-4064 1Note: The [A] and [B] keysmay be used to move thecursor to the right (A) or
viiiConventions Used In This Manual••••••••••••••••••••••••••••••••••••••••••••••••••Before you begin using this manual, it is important that you unde
VISTA-15/VISTA-15CN Installation and Setup Guide16–4If Serial or LoopNumbers do not matchafter activating thetransmitter➜If the serial/loop number com
Section 16 - Zone Programming16–5Zn ZT RC In: L01 09 10 HW: 1A summary screen appears, showing zone 01’s currentprogramming or defau
VISTA-15/VISTA-15CN Installation and Setup Guide16–610 XMIT TO CONFIRMPRESS ✱ TO SKIPThe prompt to confirm appears. This prompt appears only if youas
Section 16 - Zone Programming16–701 Zone TypeZone Disabled 004. Enter 00. This sets the zone type to Zone Disabled.Press [✱] to continue.Delete Zone?
VISTA-15/VISTA-15CN Installation and Setup Guide16–82. Select from templates. Press [✱] to display template (1 shownselected). NOTE: If necessary, p
Section 16 - Zone Programming16–9Wireless Key Predefined Default TemplatesYOU MUSTPROGRAMTHIS BUTTONLOOP 4LOOP 3ENROLL AS "BR"LOOP 1LOOP 2ON
VISTA-15/VISTA-15CN Installation and Setup Guide16–10
17–1SECTION 17Output Device Programming(✱80 Menu Mode)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Programming Options Defined♦Pr
VISTA-15/VISTA-15CN Installation and Setup Guide17–22. Zone List (ZL) is a group of zones to which the Event applies in order toactivate a particular
Section 17 - Output Device Programming17–3If a relay is energized before a 4-wire smoke detector is reset, the relay is stopped by theinterruption of
1–1SECTION 1Introduction•••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Description♦Features•••••••••••••••••••••••••••••••••••••••••
VISTA-15/VISTA-15CN Installation and Setup Guide17–4CHOICES FOR ZONE TYPES00 = Not Used 04 = Interior Follower 08 = 24-Hr Aux01 = Entry/exit #1 05 = T
Section 17 - Output Device Programming17–52. The second condition for turning on the indicator is triggering a24-hour aux. zone (Zone Type 08). Theref
VISTA-15/VISTA-15CN Installation and Setup Guide17–6
18–1SECTION 18Zone Lists(✱81 Menu Mode)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Zone List Menu Mode♦Zone List Displays♦
VISTA-15/VISTA-15CN Installation and Setup Guide18–2Cross Zoning - Zone List 04Cross zone alarm verification is an option that must be set up using zo
19–1SECTION 19Alpha Descriptor Programming••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Alpha Descriptor Programming♦Zone De
VISTA-15/VISTA-15CN Installation and Setup Guide19–2Custom Words ?0=No, 1=Yes 003. Press 1 (Yes).The Custom Words ? prompt appears.4. Press 0 (No). †
Section 19 - Alpha Descriptor Programming19–3✳ ZN 01 BACKDOOR Flashing Cursor if “6”is pressed (system isready for next word). 9. Press 6 to acce
VISTA-15/VISTA-15CN Installation and Setup Guide19–4ALPHA VOCABULARY LIST(For Entering Zone Descriptors)000(Word Space)A• 001 AIR• 002 ALARM004 ALLEY0
20–1SECTION 20Remote Programming and Control (Downloading)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Remote Programming♦E