ADEMCO Security System VISTA-15CN Instrukcja Konfiguracji Strona 64

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 63
VISTA-15/VISTA-15CN Installation and Setup Guide
15–2
25 WIRED ZONE EXPANSION 0
0 = no expander module connected
1 = 4219 connected
2 = 4229 connected
3 = 4204 connected
26 CHIME BY ZONE 0
0 =
no
(chimes on fault of any entry/exit or perimeter zone when Chime
mode activated)
1 = yes (chimes on fault of specific zones programmed in relay zone list 3
when Chime mode activated)
This option allows the
installer
to define the specific zones intended to chime
when faulted while the system is in Chime mode.
27 POWERLINE CARRIER DEVICE (X10) HOUSE ID 0
Powerline Carrier devices require a House ID. This field identifies this
House ID to the control.
If
Powerline
Carrier devices are used, they are selected in field
80.
House ID is entered in following manner:
0 = A, 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I, 9 = J,
# + 10 = K, # + 11 = L, # + 12 = M, # + 13 = N, # + 14 = O, # + 15 = P.
28 PHONE MODULE ACCESS CODE 0 | 0
1-9 = first digit of access code
or # = second digit of access code (enter # +11 for “
,”
or # +12 for “#”)
The use of a 4285/4286 VIP Module requires a 2-digit code.
Example: If desired access code is 7
, 7 is the first entry, and # + 11 (for
)
is the second entry.
NOTE: A “0” in either digit disables the phone module.
29 OUTPUT TO LONG RANGE RADIO (7720PLUS/7820/7835C) 0
Entering a 0 disables this feature; a number other than 0 enables this
feature.
If output to Long Range Radio (LRR) is selected here, all messages that are
programmed to go to the primary telephone line receiver will also be sent to
one of these radios. These messages will always be in Contact ID format (not
affected by entry in field
46). The data line and certain functions in the
radio are supervised. If communication is lost or a trouble develops, an
attempt will be made to send a message via both radio and telephone to the
Central Station.
NOTE: Normal Trouble Restore report (
71) is sent upon restoration of the
condition.
Entry is first digit of Trouble Dialer report; enter Trouble code 1–9,
B (# +11), C (# +12), D (# +13), E (# +14), or F (# +15). The second digit of
Trouble Dialer report is automatically the second digit from field
60.
U
L
For UL installations,
29 must be set to “0” (disable Long Range Radio).
NOTE: The radio should be programmed for device address 3 on the keypad
lines.
Przeglądanie stron 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 131 132

Komentarze do niniejszej Instrukcji