3–2
The length of all wire runs must not exceed 1500 feet (457m) when unshielded quad conductor
cable is used (750 feet if shielded cable is used). This restriction is due to the capacitive effect on
the data lines when quad cable is used.
2. Run field wiring from the control to the keypads (using standard 4-conductor twisted wire
cable of the wire gauge determined in step 1).
3.
Connect
remote
keypads
to terminals 4, 5, 6, and 7 on the control board, as shown in
Figure 6.
5
6
7
4
TERMINALS ON
CONTROL PANEL
BLACK
RED
GREEN
YELLOW
KEYPAD
Figure 6. Keypad Connections to the Control Board
Mounting the Keypads
To mount the keypads, perform the following steps:
1. Make sure the
addressable keypad(s)
are set to non-addressable mode (address 31), which
is the factory default setting. Refer to the instructions provided with the keypad for
address setting procedure.
2. Mount the keypads at a height that is convenient for the user. Refer to the instructions
provided with the keypad for mounting procedure.
You can either surface mount or flush mount keypads (using an appropriate Trim Ring
Kit:
6139TRK
). Refer to the mounting instructions and template included with the keypad
and/or trim ring kit for specific information.
Supplementary Power for Additional Keypads
The VISTA-15/VISTA-15CN control provides 600mA for powering keypads (up to 4) and
other devices from the auxiliary power output. The backup battery supplies power to these
keypads in the event that AC power is lost.
When the
control’s
auxiliary power load for all devices exceeds 600mA, you can power
additional keypads from a regulated 12VDC power supply (e.g.,
487-12
supplies 12V, 250mA;
488-12
supplies 12V, 500mA). Use a
UL
Listed, battery-backed supply for UL installations.
The 487-12/488-12
power
supplies have a backup battery that can power these keypads in the
event of AC power loss to the main supply.
Keypads powered from supplies that do not have a backup battery
will not function
when AC
power is lost. Therefore, be sure to power at least one keypad from the control's auxiliary power
output.
Connect the additional keypads as shown in
Figure 7
, using the keypad wire colors shown. Be
sure to observe the current ratings for the power supply used.
Przeglądanie stron 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 131 132

Komentarze do niniejszej Instrukcji

Brak uwag

Maxon SP-200K Series manuels

Manuels d'utilisation et guides de l'utilisateur pour Les radios bidirectionnelles Maxon SP-200K Series.
Nous fournissons des manuels en pdf 1 Maxon SP-200K Series à télécharger gratuitement par type de document : Instructions d'exploitation






Plus de produits et de manuels pour Les radios bidirectionnelles Maxon

Modèles Type de document
GMRS-21X Manuel du propriétaire   Maxon GMRS-21X Owner`s manual, 19 pages
SL 25 Manuel de l'utilisateur   Maxon - RadioPics Database, 39 pages
GMRS-50 Guide de l'utilisateur   Maxon GMRS-50 User`s guide [en] , 18 pages
GMRS-50 Manuel du propriétaire   Maxon GMRS-50 Owner`s manual, 24 pages
SL6000 Series Manuel de l'utilisateur    Maxon SL6000 Series User manual, 20 pages
S5 PMR446 Manuel de l'utilisateur    Maxon S5 PMR446 User manual, 17 pages
SL1000 Manuel de l'utilisateur       Maxon SL1000 User manual, 108 pages
SP-340 Manuel de service   Maxon SP-340 Service manual, 52 pages
S5 PMR446 Manuel de l'utilisateur       Maxon S5 PMR446 User manual, 93 pages
SP200 Manuel de service   Maxon SP200 Service manual, 95 pages
GMRS-50 Manuel du propriétaire   Maxon GMRS-50 Owner`s manual, 16 pages
SL6000 Series Manuel de service   Maxon SL6000 Series Service manual, 27 pages
sd170e Spécifications   Maxon sd170e Specifications, 107 pages