5–1
SECTION 5
Wired Zone Expansion
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
♦
Installing Zone Expansion Units
♦
Connections and Setup
♦
Programming Wired Expansion Zones
♦
Checkout Procedure for Wired Expansion Zones
••••••••••••••••••••••••••••••••••••••••••••••••••
Installing Zone Expansion Units
You can add 8 wired
EOLR
zones to the basic
control's
6 zones, for a total of 14 wired zones,
by using a
4219
Wired Expansion Unit or
4229
Wired Expansion/Relay Unit.
Location • You can mount an expansion unit within the control cabinet if space
permits. Otherwise, mount the unit outside the cabinet.
Supervision • Units are supervised against removal. Keypads display CHECK and
ZONE 09 if a zone expander is disconnected.
• Units have
tamper protection
for security when mounted outside of
the cabinet.
Zone Information • Assign zone numbers 10–17 for the eight wired expansion loops
(designated A to H in
Figure 10
and
Figure 11
)
. You can program
these zones individually (in
✱
56
Zone Programming Mode or
✱
58
Expert Programming Mode
). Expansion zones must also be
programmed as input type 2 (AW) when prompted.
Connections and Setup
To add an expansion module, perform the following steps:
1. Connect the 4219 or 4229 module to the control's keypad terminals (see
Figure 10. Wiring
Connections
- 4219 Expansion Module
or
Figure 11. Wiring Connections - 4229
Expansion/Relay Module
)
.
2. Set the 4219 or 4229's
DIP switch
for device
address
“1” (switch 2 in the OFF position and
switches 3, 4, 5 in the ON position). Switch 1 determines expansion zone A's response
time (ON = normal response, OFF = fast response). For location of the DIP switch in both
the 4219 and 4229 units, see figures that follow on next page.
For additional information, see instructions supplied with the 4219 and 4229 modules.
OFF ON
1 2 3 4 5
ON
< <