Section 15 - Data Field Descriptions
15–11
81 ZONE LISTS FOR OUTPUT DEVICES
Interactive Menu mode applicable if
25 is programmed for a 4204 or 4229,
or if Powerline Carrier devices are being used.
Cross Zone and NIGHT-STAY zone lists are also programmed in this field.
Refer to Section 18: Zone Lists for detailed procedure.
82 CUSTOM ALPHA EDITING
Intera
ctive Menu mo
de used to program zone descriptors.
Refer to Section 19: Alpha Descriptor Programming for procedure.
84 AUTO STAY ARMING 0
0 = no 1 = yes
With this field enabled (1 = yes) and system armed in AWAY (or MAXIMUM)
mode by a non-RF device, the system automatically reverts to armed STAY
(or INSTANT) mode if a door is not opened and shut within the programmed
exit delay time. An Opening report followed by an Armed Stay report is sent
to the Central Station. Any RF device that arms the system AWAY (or
MAXIMUM) overrides this feature and the system remains armed in the
AWAY (or MAXIMUM) mode.
85 CROSS ZONE TIMER
(in seconds)
0
0 = 30; 1 = 45; 2 = 60; 3 = 90; 4 = 120; 5 = 180; 6 = 240
Sets the maximum amount of time in which two cross zones (zone list 04)
must be tripped in an armed system to send an Alarm message to the
Central Station. If only one cross zone is tripped during this time, a Trouble
message (report) is sent to the Central Station.
This option not for use in UL installations.
87 ALARM PAGER DELAY TIME 3
0 = none; 1 = 1 minute; 2 = 2 minutes; 3 = 3 minutes
This field determines the delay of alarm reports to the pager. This gives the
Central Station enough time to verify the alarm report that it received,
before the dialer is tied up trying to dial the pager.