Section 5 - Zone Programming
59
PROMPT VALID ENTRIES EXPLANATION
Keyd A022-4063
Rcvd A022-4064 3
Not Confirmed
If the serial number transmitted
does not match
the
serial number entered, a display similar to the one at left
appears.
If it doesn't match,
press any button on the transmitter
once again. If a match is not obtained, press the [#] key
and then enter the correct serial number (steps 7 through
10 above).
If the serial number transmitted
matches
the serial
number entered, the keypad beeps 3 times and returns
you to step 7 above to enter the starting zone for the next
wireless key.
After all wireless keys are programmed, enter 00 at the
ENTER START ZONE prompt.
NOTE:
Following the successful enrollment of each wireless device, remove
ONE
of the serial number labels
from the device and affix it in the appropriate column on the ENROLLED TRANSMITTERS worksheet of
the Programming Form. Then enter the other information (zone number, zone type, loop number, etc.)
relevant to that device. This information will be useful if any troubleshooting is needed later on. The
installer may want to consider leaving this worksheet at the site (in the panel cabinet).
Wireless Key Predefined Default Templates
YOU MUST
PROGRAM
THIS BUTTON
LOOP 4
LOOP 3
ENROLL AS "BR"
LOOP 1
LOOP 2
ON
OFF
Figure 5-2. 5804 Wireless Key
Transmitter
LOOP 3
LOOP 1
LOOP 2
LOOP 4
(YOU MUST
PROGRAM
THIS BUTTON)
RED/YELLOW
LED
GREEN/YELLOW
LED
ENROLL AS "BR"
Figure 5-3. 5804BD 2-Way Wireless
Key Transmitter
For 5804
For 5804BD
Loop
Function
Zone Type
Loop
Function
Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 No Response 23
3 Arm AWAY 21 3 Arm AWAY 21
TEMPLATE 1
4 No Response 23
TEMPLATE 4
4 Disarm 22
Loop Function Zone Type
Loop Function Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 Arm STAY 20
3 Arm AWAY 21 3 Arm AWAY 21
TEMPLATE 2
4 Arm STAY 20
TEMPLATE 5
4 Disarm 22
Loop Function Zone Type
Loop Function Zone Type
1 24-hour Panic 07
1 24-hour Panic 07
2 Disarm 22 2 Arm STAY 20
3 Arm AWAY 21 3 Arm AWAY 21
TEMPLATE 3
4 Arm STAY 20
TEMPLATE 6
4 Disarm 22
Note:
These transmitters are
not intended for use in
UL installations.