VISTA-128B Installation Instructions
23-6
010 INPUT TYPE
RF Xmitter 3
Note that input types 4 & 5
are valid for certain 5800
Series transmitters only (e.g.,
5801, 5802, 5802CP & 5803).
Input type 10 is
applicable only if
PassPoint ACS is
installed with the Vista
Gateway Module.
If response type 28 was
selected, the input type
MUST be 00.
Enter the input device type as follows:
00 = not used
01 = hardwired
03 = supervised RF transmitter (RF type)
04 = unsupervised RF transmitter (UR type)
05 = RF button-type transmitter (BR type)
06 = serial number polling loop device (SL type)
07 = DIP switch-type polling loop device
08 = right loop of DIP switch type device.
09 = keypad input (code + #73, code + #74)
10 = PassPoint ACS input
Right loops refer to the use of the right loop on a 4190WH Zone
Expander Module and/or 4278 PIR, which allow hardwired
devices to be monitored by the polling loop.
If programming hardwired, or DIP switch polling loop devices,
the summary display appears after completing this entry.
Press [*] to continue.
010 V-PLEX RELAY?
1 = YES 0 = NO
If input type 6 was selected, this prompt will be displayed.
Enter
1
if using a 4101SN relay module for this zone.
Otherwise enter
0
.
010 CONS ECP ADDR
(01-31) 01
If input type 09 was selected, this prompt will be displayed.
Enter the ecp address of the keypad that is being used for
entry/exit for this access point
(01-31)
.
010 ACS ZONE NO
(00-31) 01
If input type 10 was selected, this prompt will be displayed.
Enter the PassPoint ACS zone ID that this VISTA zone maps to
(00-31)
.
010 LOOP #
1
The cursor should now be flashing on the loop number. The
default is 1. To accept this, press [*]. If a different loop
number is being used on this device, enter the loop number (1-
4) and press [*] to continue. (The loop designations for various
RF transmitters are shown in
Figure 25-1
.)
The loop number
must be entered here, whether using Zone Programming
or Sequential Mode to "enroll" serial numbers.
If you
want to delete the serial number, enter
0
and press [*]. The
system will then prompt, "DELETE S/N?" Press
1
(YES) to
complete the delete sequence. This process deletes the serial
number only,
not
the loop number. The assumption is that the
proper loop number was programmed, but the wrong serial
number was enrolled.