ADEMCO Vista AT Podręcznik Użytkownika Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
– 6 –
Before Arming (Ready [
] Key)
Not Ready
Before arming the system, you should close or bypass all protected doors, windows and
(using [
] key), other protection zones.
Press [
] to display open zones (do not enter code first).
To bypass zones, see the Bypassing Zones section below.
Some systems, if programmed, may allow arming even if selected zones in the exit route are
faulted. Depending on the programming, these zones, if left faulted when exit delay expires,
will either be automatically bypassed or cause an alarm. See your installer.
Voice Status: Voice Keypads (if installed), can announce system status and faulted zones (up to 3 zone
descriptors) if Voice Status is on.
To turn Voice Status on/off: [#] + [0] [2] [4]
(Also turns on Voice Chime mode; see Chime mode section)
To announce System Status: Press [
] STATUS key once.
To announce faulted zones: Press the [
] STATUS key a second time within 5
seconds of the first press
Ready All zones are closed or bypassed and you can now arm the system.
Some systems, if programmed, may allow arming even if selected zones in the exit route are
faulted. Depending on the programming, these zones, if left faulted when exit delay expires,
will either be automatically bypassed or will cause an alarm. See your installer for your
system’s programming.
Bypassing Zones
Bypass Notes
You can bypass zones before arming the system or while the system is already armed.
Your system may have a limit on the total number (1-7) of zones you may bypass (check with
your installer).
Bypassed zones are unprotected and will not cause an alarm if violated.
The system will not allow fire zones to be bypassed.
Zones are automatically unbypassed when the system is disarmed.
Vent Zones:
Y
our system may have certain windows set as “vent” zones, which are
automatically bypassed if left open when arming the system (you do not need to manually
bypass them). However, if a vent zone window is closed after arming, it becomes protected
and will cause an alarm if opened again while the system is armed.
To Bypass
Security code + [6] BYPASS + zone numbers
Zones Use 2-digit zone number(s) for the zone(s) to be bypassed.
Single digit zone numbers must be preceded by a zero (e.g., 05, 06).
When finished, the keypad will momentarily display a "Bypass" message for each bypassed
zone number.
Wait for all bypassed zones to be displayed, then arm the system as usual.
When armed, “ZONE BYPASSED” is displayed with the arm message.
To display bypassed zones prior to arming, enter your security code and press the [6]
BYPASS key.
Quick Bypass
Security Code+ [6] BYPASS + [#]
Wait for all bypassed zones to be displayed, then arm the system.
Active? ____ In a few moments, all open zones will be displayed and automatically bypassed. Make sure
that only those zones that you wish to leave unprotected are bypassed, and that there are
no other zones unintentionally left open.
Allows you to easily bypass all open (faulted) zones without having to enter zone numbers
individually. This feature is useful if, for example, you routinely leave certain windows open
when arming at night.