
– 5 –
Exit/Entry Delays
Exit Delay • When you arm the system, the system gives you a programmed amount of time to leave
through the designated exit door and/or certain other zones (if programmed) without
setting off an alarm.
• A slow beeping, if programmed, will sound during the exit delay period until the last 10
seconds, which then changes to fast beeping.
• If programmed, the keypad displays a countdown of the number of seconds of exit delay
remaining.
• When exit delay expires, all zones become protected and cause an alarm if opened.
• Your system may have been programmed such that exit delay remains in effect until a final
zone (e.g.,, exit door) has been closed for five seconds. Ask your installer.
Exit Delay •
••
• Press the [∗
∗∗
∗] key if armed in STAY mode to restart the exit delay timer.
Restart • This gives you time to open the entry/exit door to let someone in after arming STAY. The
system (If programmed), automatically rearms when exit delay expires, which avoids
having to disarm the system and then rearm it again.
• When the system is armed AWAY, reopening and closing the entry/exit door before exit
delay time expires (e.g., reentering to get a forgotten item) will restart the exit delay time.
Entry Delay • Gives you time to disarm the system when you re-enter through the designated entrance
door. You must disarm the system before the entry delay period ends, or an alarm will
occur.
• See your installer for your delay times.
Partition 1 Partition 2 Common Partition
Delay 1: _______ seconds Delay 1: _______ seconds Delay 1: Same as Partition 1
Delay 2: _______ seconds Delay 2: _______ seconds Delay 2: Same as Partition 1
Exit Alarms • If an entry/exit door or interior zone is faulted when the exit delay ends (e.g., exit door lef
open), the system sounds an alarm and starts the entry delay timer.
• Disarming the system before entry delay ends stops the alarm sound.
• The message "CANCELED ALARM" or "CA" is displayed on the keypad, along with a zon
number indicating the faulted zone.
• No message is sent to the Central Monitoring Station.
• If you do not disarm the system before the entry delay ends, and an entry/exit door o
interior zone is still open, the alarm sound continues and an "exit alarm" message is sent t
the Central Monitoring Station. The message ""EXIT ALARM" or "EA" and the faulted zon
number is displayed on the keypad.
• To stop the alarm, the system must be disarmed (your code plus OFF), to clear the display,
enter your code plus OFF a second time.
• An “exit alarm” also results if an entry/exit door or interior zone is faulted within tw
minutes after the end of the exit delay.
To clear an exit alarm:
• Make the open zone intact, then
• Enter your code plus [1] OFF to clear the display.
Your system may have been programmed for this feature to minimize false alarms sent to the
Central Monitoring Station. Ask your installer if "Exit Alarm" is active in your system. If so,
check this box: [ ]
Part. 1: _____ sec
Part. 2: _____ sec
Common: Same as
Komentarze do niniejszej Instrukcji