15–6
Press
62 AC LOSS REPORT CODE
Reports with Subscriber No. Timing of this report is random with
up to a 48-minute delay. The Restore report has a random delay
of up to about 12 minutes. If AC restores before the report goes
out, there is no AC restore report.
Press
63 LOW BAT REPORT CODE
This will be sent when a low battery condition exists in the
system’s standby battery (connection to the standby battery is
checked every 3 minutes (CSFM requirement)).
Press
64 TEST REPORT CODE
This is sent periodically to test that the communicator and phone
lines are operational (frequency of report is selected in field
51).
Press
65 OPEN/EXIT ALARM REPORT CODE, 1st DIGITS
Open Report Code : To enable, enter a code (or 0 to disable) in
the left-hand box.
For expanded or 4+2 reporting,
2nd digit = User #.
Exit Alarm Report Code: To enable, enter a code (or 0 to
disable) in the right-hand box. If enabled, any alarm from an
exit or interior zone occurring within two minutes after the
end of the exit delay will send a special message indicating exit
alarm to the central station, and a zone indication and "Exit
Alarm" or "EA" is displayed on the keypad.
If an exit or interior zone contains a fault as the exit delay
ends, the local bell and keypad sound continuously.
a)
If the subscriber then disarms the system before the ensuing
ENTRY delay ends
, no message is transmitted to the central
station, but a zone indication and "Canceled Alarm" or "CA" is
displayed on the keypad.
b)
If the system is not disarmed before that entry delay ends
, a
special message indicating Exit Alarm is sent to the central
station and a zone indication and "Exit Alarm" or "EA" is displayed
on the keypad.
For expanded or 4+2 reporting
, a 2nd digit is sent, and is the
same as the 2nd digit of the zone alarm report code programmed
in field 56.
For Contact ID reporting
, Event code 374 and the zone number is
sent.
There is no restore message for an Exit Alarm report.
Press
66 ARM AWAY/STAY REPORT CODES
This option allows for independent programming of AWAY and
STAY reports . 2nd digit of Report is User No., if expanded or 4+2
reporting is selected.
Press
67 RF XMTR. LOW BATTERY REPORT CODE
This is sent in the event that a wireless transmitter low battery
condition exists.
Press
68 CANCEL REPORT CODE
This is sent upon disarming of the system after an alarm condition
was reported.
Press
70 ALARM RESTORE REPORT CODE, 1st DIGIT
This is sent when the zone that caused an alarm is restored to its
non-faulted condition. 2nd digit is automatically sent as the 2nd
digit of the zone alarm report code programmed in field
56, if
expanded or 4+2 reporting is selected.
Press
71 TROUBLE RESTORE REPORT CODE
This is sent when a trouble in a zone is restored.
Press
72 BYPASS RESTORE REPORT CODE
This is sent when a zone that has been bypassed is un-bypassed.