Example 1.
Pager displays: 1234911–004
This indicates that Subscriber No. 1234’s system is reporting an Alarm (911),
due to zone 4 being faulted (004).
Example 2.
Pager displays: 1234001005
This indicates that Subscriber No. 1234’s system is reporting an opening (001)
by User 5 (005).
Note that no restore reports are sent to the pager.
Important
: Do not use AAV when Paging or Alarm Reports are being sent to
a Secondary number. If this is done, the call to the Secondary number by the
communicator after the alarm report will prevent the AAV from taking control
of the phone line, and the AAV “Listen in” session cannot take place.
Press
48 15-SECOND DIALER DELAY, BURGLARY
Enter 0 for no, or 1 for yes. Default is 0 (no delay).
Press
49 PERIODIC TEST REPORT
Select the desired test report interval.
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days. Default is 0
(none). Test Report Code entered in field
64 is sent.
Reports with Subscriber No.
Press
50 SESCOA/RADIONICS SELECT
0 = Radionics (0–9, B–F reporting)
1 = SESCOA (0–9 only reporting)
Select 0 for all other formats. Default is 0.
TO PROGRAM SYSTEM
STATUS AND
RESTORE REPORT
CODES
(
60 –
68,
70 –
75)
With a 3+1 or 4+1 Standard Format: Enter a code in the
first digit
box:
1–9, 0, B, C, D, E, or F. Enter "# + 10" for 0, "# + 11" for B, "# + 12" for C,
"# + 13" for D, "# + 14" for E, "# + 15" for F.
A "0" (
not
"# + 10") in the
first digit
box will disable a report.
A "0" (
not
"# + 10") in the
second digit
box (if any) will result in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in
both
boxes (1st and 2nd
digits) for 1–9, 0, or B–F, as described above.
A "0" (
not
"# + 10") in the
second
box will eliminate the expanded message
for that report.
A "0" (
not
"# + 10") in
both
boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than "0") in the
first
box, to enable zone to report This is an "enabling" code only and is
disregarded in the actual reporting to the central office. Entries in the
second
boxes will be ignored.
A "0" (
not
"# + 10") in the
first
box will disable the report.
Examples:
For Code 3 (Single Digit), enter: 3 0
For Code 32 (Two Digits), enter: 3 2
For Code B2 (Hexadecimal) enter: # + 11 2
Press
60 TROUBLE REPORT CODE
This will be sent if a zone goes into trouble.
Press
61 BYPASS REPORT CODE
This will be sent when a zone is manually bypassed.