– 5 –
VISTA-128BP/VISTA-250BP Programming Form
Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system,
see the
Partition-Specific Fields
section for programming these fields. Standard default (*97) values are shown in brackets [ ];
otherwise, default = 0.
*00 INSTALLER CODE | | |
Enter 4 digits, 0-9 [4140]
*04 ENABLE RANDOM TIMERS
1
2
3
4
5
6
7
8
Enter 1 to make available the randomizing of pre-programmed
time driven events for each partition. [0=disable].
*05 SYSTEM EVENTS NOTIFY [0]
1=yes, (messages sent via the RS232 port).
0=no, (no messages sent).
*06 QUICK EXIT [1]
1=enable; 0=disable
Must be 0 for UL installations.
*09 ENTRY DELAY #1 [02] |
00, 02-15 times 15 seconds
Maximum "03" for UL.
SIA Guidelines: The entry delay time and Burg Alarm Comm
Delay (field *88) combined cannot exceed 1 minute.
*10 EXIT DELAY #1 [04] |
00, 03-15 times 15 seconds
Maximum "04" for UL installations.
SIA Guidelines: Minimum 45 seconds “03”.
*11 ENTRY DELAY #2 [02] |
00, 02-15 times 15 seconds (must be longer than Entry Delay
#1). Maximum "03" for UL installations.
SIA Guidelines: The entry delay time and Burg Alarm Comm
Delay (field *88) combined cannot exceed 1 minute.
*12 EXIT DELAY #2 [08] |
00, 03-15 times 15 seconds (must be longer than Exit Delay
#1). Maximum "04" for UL installations.
SIA Guidelines: Minimum 45 seconds “03”.
*13 ALARM SOUNDER DURATION [04] |
01-15 times 2 minutes. Must be minimum 16 minutes for UL
installations. SIA Guidelines: Must be minimum 6 minutes.
*14 BURGLARY OR RS232 INPUT [0]
Enter 1 to set terminal 23 as a RS232 input to enable system
to receive serial data (75 baud) via terminal 23.
Enter 0 to enable terminal 23 as burglary input for zone 9.
*15 KEYSWITCH ASSIGNMENT [0]
Enter partition in which keyswitch used,
1-8; 0=disable
*16 CONFIRMATION OF ARMING DING [0]
1=enable; 0=disable.
Must be "1" for UL Installations.
*17 AC LOSS KEYPAD SOUNDING [0]
1=yes; 0=no
*19 RANDOMIZE AC LOSS REPORT [0]
1=10-40 min; 0=normal report (about 2 min. after AC loss).
*20 VIP MODULE PHONE CODE | |
Enter 01 - 09 for the first digit; enter [00], [11]
11 for “*” or 12 for “#” for the second digit.
Must be set to "0" for UL installations.
*21 PREVENT FIRE TIMEOUT [0]
1=No timeout; 0=Timeout.
*22 KEYPAD PANIC ENABLES [001]
1=enable; 0=disable 995 996 999
*23 MULTIPLE ALARMS [1]
1=yes; 0=no
*24 IGNORE EXPANSION ZONE TAMPER [0]
1=Ignore; 0=Enable tamper for RF and RPMs.
Must be "0" for UL installations if using these devices.
*25 BURG.TRIGGER FOR RESPONSE TYPE 8 [1]
1=enable; 0=disable
*26 INTELLIGENT TEST REPORTING [0]
1=yes (no report sent if any other report was recently sent);
0=no (send report at programmed interval, field *27)
Must be 0 for UL installations.
*27 TEST REPORT INTERVAL [0024] | | |
Enter interval in hours, 0001-9999; 0000=no report;
Max. 0024 for UL installations.
*28 POWER UP IN PREVIOUS STATE [1]
1=yes; 0=no; "1" for UL installations.
*29 QUICK ARM [1]
1=yes; 0=no
*30 TOUCHTONE OR ROTARY DIAL [0]
1=TouchTone; 0=rotary
*31 PABX ACCESS CODE | | | |
00-09; B-F (11-15)
*32 PRIM. SUBS. ACCT # | | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
*33 PRIMARY PHONE NUMBER
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause
*34 SECONDARY PHONE NUMBER
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause