– 26 –
PROMPT
EXPLANATION
Enter the rest of the codes in the same manner. Other report codes in System Group #1 are:
• Opening (Disarm) Also, enable this if you desire Callback Requested reports (the panel answers a
phone call from the downloader).
• System Low Battery
• Low Battery Restore
• AC Loss
• AC Restore
• Periodic Test
• Power
• Cancel
• Program Tamper
Once you have entered these report codes, the system prompts you with the Quit menu.
QUIT REPORT MENU
1 = YES 0 = NO 0
If you have completely finished entering report codes, press 1 (Y) to quit
Report Code Programming
. If you
wish to enter other system report codes, enter 0 (N).
Press [✱] to continue.
System Group #2 Codes
PROMPT
EXPLANATION
SYSTEM GROUP #2 ?
1 = YES 0 = NO 0
To enter System Group #2 codes, press [1] (Y).
STAY
1st 00 2nd 00
Enter the first digit of the Arm-STAY report. Press [✱]. Enter the second digit of the report. If the user
number is desired as the second digit, enter 01 (not necessary for Contact ID or High Speed formats).
Press [✱] to continue.
Enter the rest of the codes in the same manner. Other codes in System Group #2 are:
• Time Set, Log Reset
• Log 50%, 90% Full
• Event Log Overflow
• Exit Error by Zone
• Exit Error by User
• Recent Close
Once you have entered these report codes, the system prompts you with the Quit menu.
QUIT REPORT MENU
1 = YES 0 = NO 0
If you have completely finished entering report codes, press [1] (Y) to quit
Report Code Programming
. If
you wish to enter other system report codes, enter 0 (N).
Press [✱] to continue.
System Group #3 Codes
PROMPT
EXPLANATION
SYSTEM GROUP #3 ?
1 = YES 0 = NO 0
To enter System Group #3 codes, press [1] (Y).
EARLY OPEN
1st 00 2nd 00
Enter the first digit of the Early Opening Report Code. Press [✱]. Enter the second digit of the report code.
If the user number is desired as the second digit, enter 01 (not necessary for Contact ID or High Speed
formats).
Press [✱] to continue.
Komentarze do niniejszej Instrukcji