– 32 –
Device Programming
This menu is used to program keypads, receivers, and relay modules, etc.
Device Address 00 is always set as an alpha keypad assigned to Partition 1 with no sounder suppression
options, and these settings cannot be changed.
From Data Field Programming mode, press #93 to display "ZONE PROG?" Press [0] repeatedly to display "DEVICE PROG?"
PROMPT
EXPLANATION
DEVICE PROG?
1=YES 0=NO 0
Press [1] to enter
Device Programming
.
DEVICE ADDRESS
01-30, 00=QUIT 01
The device address identifies the device to the control. Enter the 2-digit device address number to match
the device's physical address setting (01-30).
Press [✱] to accept entry.
Select the type of addressable device as follows:
00 = device not used 05 = Do Not Use
01 = alpha keypad (6160/6160CR-2) 06 = communicator
03 = RF receiver (5881) 09 = Do Not Use
04 = output relay module (4204) 10 = Do Not Use
DEVICE TYPE
00
Press [✱] to accept entry.
Alpha Keypad
PROMPT
EXPLANATION
01 CONSOLE PART.
1
If you selected device type 01 (alpha keypad), this prompt appears. Enter the addressable device's default
partition number (01 to maximum number of partitions programmed for system in field 2*00). This is the
primary partition for the device. Enter 9 to make this keypad a "Master" keypad for the system.
Press [✱] to accept entry.
01 SOUND OPTION
00
If you entered device type 01 (alpha keypad), this prompt appears. Keypads can be individually
programmed to suppress arm/disarm beeps, entry/exit beeps and chime mode beeps. This helps prevent
unwanted sounds from disturbing users in other areas of the premises.
Enter a number 00-03 for the keypad sounding suppression options desired for the keypad as follows:
00 = no suppression
01 = suppress arm/disarm & entry/exit beeps
02 = suppress chime mode beeps only
03 = suppress arm/disarm, entry/exit and chime mode beeps
Press [✱] to accept entry.
01 KEYPAD GLBL?
0
If you entered device type 01 (alpha keypad), this prompt appears. Each keypad can give users with access
to multiple partitions the ability to arm and disarm those partitions from it. To enable this keypad for global
arming/disarming, enter 1. To prevent the ability to use this keypad for global arming/disarming, enter 0.
Press [✱] to accept entry.
01 AUI ?
1 = YES 0 = NO 0
Do Not Use. Must be set to “0”.
Press [✱] to accept entry.