ADEMCO Vista-20HW Instrukcja Naprawy Strona 77

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 100
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 76
SYSTEM STATUS *59
REPORT CODES
(*59-W3)
*60
*61
*62
*63
*64
*65
*66
*67
*@
EXIT ERROR REPORT CODE (Seeboxpreviously)
•1
If the systemis armedandan Entry/Exitor Interiorzoneis still open
after the exit delay time has expired, an alarm will sound at the
keypadand externalsounder(keypadalso displays “Exit Alarm”). If
the system is disarmed before the end of the entry delay that
immediatelyfollows,the alarm soundingwill stop and no message
wiIl be sent to the central station. The keypad will display CA
(fied-word keypads)orCANCELEDALARM (Alphakeypads).
If the system is not disarmed before the end of the entry delay
mentionedabove,and an Entry/Exitor Interiorzone is still open, an
‘exit alarm” message will be sent to the central station if an
Exit Error Report code is selected in this field. The keypadwill
display EA (fixed-wordkeypads)or EXIT ALARM (Alpha keypads),
andthe zdarmsoundingwillcontinueuntil the system is disarmed(or
timeoutoccurs).
An “ExitAlarm” conditionwillalsoresultif a faultoccursin an exitor
interiorzonewithin2 minutesfollowingthe end of the exitdelay, and
an “exitalarm”messagewillbe sentto the centralstation.
If ContactID formathas been programmed,the message will contain
the zonenumbersnd errorcode374 (Troubl*Exit Error)to definethe
alarm as an Exit Error(ratherthan E/E or Interior).If 4+2 formatis
used,the digitenteredin this fieldwill be sent followedby the second
digitofthe programmedalarmcodeforthat zone. If 3+1 or4+1 format
is used, onlythe digitenteredin this field will be sent. This message
will go to the PrimaryPhoneNo. Under any of these conditions,no
Restoremessagewillbe sent.
If “O”is enteredin this field,no specialmessagewill be sent, only the
regularalarmandalarmrestorecodeforthe zone.
TROUBLE REPORT CODE (Seeboxpreviously)
m
BYPASS REPORT CODE (Seeboxpreviously)
m
AC LOSS REPORT CODE
m
See box on previouspage. Reportswith Partition 1 SubscriberNo.
Timing of this reportis randomwith up to a 4-hour delay. If AC
restoresbeforethe reportgoesout,thereis noAC restorereport.
LOW BAT REPORT CODE
m
Seebox. ReportswithPartition1 SubscriberNo.
TEST REPORT CODE
Seebox. Periodic Reports with Partition
OPEN REPORT CODE
See box on previous page. 2nd digit =
reporting is selected.
ARM AWAY/STAY REPORT CODE
m
1 Subscriber No.
•1
User #, if expanded or 4+2
r-i---l
This option allows for independent programming of AWAY and~Y
reports for each partition. 2nd digit of report is User No. if expanded
or 4+2 reporting is selected.
RF XMTR LOW BAT REPORT CODE. (NOT
USED)
CANCEL REPORT CODE (Seebox onpreviouspage.)
m
-77-
Przeglądanie stron 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 99 100

Komentarze do niniejszej Instrukcji

Brak uwag