Event Logging
Alarm output
The telephone lin;vofiage can be monitored to supervise the phone line
connection. The panel must be connected to a proper earth
ground or you will get a false line cut indication if this feature
is enabled.
The loss of the line can optionally cause a local display, or a display and
trouble sound.
Event Logging feature keeps a record of selected events in a history log
(UP to 48 events). All control and readout from the log is done via
Ademco V-LIN@ downloading software only.
Provides a 12VDC, 2 AMP output that can drive the compatible
sounders listed in the EXTERNAL SOUNDERS section (assumesa fully
chargedbatteryis connected).
Steady output for Burglary/Panic, or temporal pulse output (3 pulses
pause 3 pulses pause -3 pulses. . .) for Fire
Uses current limiting circuitry for protection
Auxiliary
pow- Output
Provides 12VDC, 600 mA maximum. Uses current limiting circuitry for
protection.
This output interrupts for smoke detector reset if 4-wire smoke
detectors are used.
progralmnin~
Prograrqmed options are stored in electrically erasable, non-volatile
EEROM memory (information can be reprogrammed at any time and
will not be lost in the event of a power loss).
The system can be uploaded, downloaded, or controlled via an IBM
compatible computer, Ademco V-LINI@ downloading software and a
HAYES modem specified by Ademco.
Keypad programming consists of:
Data field programming
Interactive (menu) mode programming
communication Formats
supfborted
Ademco Low Speed (Standard or Expanded)
Sescoa/Radionics (Standard or Expanded)
Ademco Express
Ademco Contact ID
Zone Deecriptore
You can assign Alpha descriptors to all zones (usefil only when using
Alpha keypads and/or the 4285 VIP (VISTA Interactive Phone) module.
AC
power Supply
Uses 1321/TF2, 11OVACplug-in transformer with 16.5VAC 25VA output,,
unless Powerline Carrier devices (ex. X-10 type) are used, in which case a
4300 Imansformer module must be used.
Back-up Battery
Rechargeable (Gel type) 12VDC, 4AH minimum (Ademco No. 467).