CHOICES FOR ZONE TYPES
** Use O(Any)for
PartitionNo. (P)
entry.
*“* Or at Disarming,
whicheveroccurs
earlier.
~
02 stop: Zn List
No List
o
I
02 stop:
Zn Typ
Not
Used
00
I
02 stop:
Part
Any Partition A
02 .AEVZLZT P
S1-roooool
00= NotUsed 04= InteriorFollower 08=24 HrAux
01= Entry/Exit#l 05= TroubleDay/AlarmNight
09= FireTrouble
I
02= Entry/Exit#2
06= 24HrSilent 10=Interiorw/Delay
03=Perimeter 07= 24HrAudible 23. NoAlarmResponse
24. SilentBurglary
CHOICES FOR SYSTEM OPERATION
20= Arming+tay
36= **AtBellTimeout***
42= **SystemBatteryLow
21. Arming-Away
38= Chime 43=CommunicationFailure
22. Disarming(Code+OFF) 39=AnyFireAlarm
52=
KiSSOff
31= EndofExitTime
40= Bypassing 58= Duress
32= StartofEntryTime 41= **ACPowerFailure
33= AnyBurglaryAlarm
Enter (if applicable) the partition number 1 or 2 (or Ofor any).
Press the [*] key to continue.
If a zone list will be used to STOP, or restore, the device action, enter the zone
list number 1,2, or 3 (to be programmed in *81 mode). If not used, enter O.
Press the [*] key to continue.
If a zone type or system operation will be used to STOP the device action,
enter the appropriate two digit code (see the “ZT’ choices listed above). If not,
enter 00. Press the [*] key to continue.
Enter (if applicable) the partition number 1 or 2 (or Ofor any). Press the
[*I
key to continue.
This screen again displays a summary of the current device START
programming. Press the [*] key to continue.
This screen again displays a summary of the current device STOP
programming. Press the [*] key to continue.
Enter 1 if using a Powerline Carrier Device (X-1O); if not, enter O.
The display then returns again to the first screen so that the next device
number to be programmed can be entered, or enter [0][0] to end device
Example of
A lamp is to be turned on via a Powerline Carrier device (X-1O) when any one
Output Device
of 3 specific zones sxe faulted, or when any 24hour auxiliary zone is faulted.
Programming
We want to be able to turn off the lamp manually without affecting the
arming status of the system.
To program this, we would do the following
. In *8O interactive mode we choose output Device 01 and program the Ac-
tion (A) to be “2” (Close and stay closed). The Event we are looking for to
start the Device action is a fault, so we will program “2” in (EV). We will
use Zone List 1 for the 3 specific zones, so we will program “l” in (ZL), (and
we will program these 3 zones in *81’s Zone List 1).
The second condition for turnin
g on the indicator is triggering a 24-hour aux.
zone (Zone Type 08), so we will program (ZT) as “08”.
Next, enter the Partition number (P) in which you want the triggering of a
24hour zone to occuq enter 1 or 2, or enter Ofor any partition.
-37-