Symphony (AUI) Enable
FIELD TITLE and DATA ENTRIES EXPLANATION
*189
Symphony (AUI) Enable
0 = disabled
1 = partition 1
2 = partition 2
3 = common lobby
APPLIES TO VISTA-20PS ONLY.
Enter each AUI’s home partition.
NOTE: A minimum of one standard keypad must also be installed
when AUI is used.
Keypad Programming Fields
NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
FIELD TITLE and DATA ENTRIES EXPLANATION
*190
Keypad 2 Device Address 17
Entry 1 – Partition Assignment:
0 = keypad disabled
1 = partition 1
(VISTA-20P)
/enabled
(VISTA-15P)
2 = partition 2
3 = common
Entry 2 – Sound Option:
0 = no suppression
1 = suppress arm/disarm and E/E/ beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E/ beeps and
chime beeps
Keypad 2
Entry 1: For VISTA-20P, enter the partition in which the keypad is
located; for VISTA-15P, enter 1 to enable, or 0 to disable.
Entry 2: Enter the desired sound option for this keypad.
NOTE:
Address 16 is reserved for keypad 1, which is automatically
set to partition 1 with all sounds enabled.
*191
Keypad 3 Device Address 18
See field *190 for entries.
Keypad 3
See field *190 for explanation.
*192
Keypad 4 Device Address 19
See field *190 for entries.
Keypad 4
See field *190 for explanation..
*193
Keypad 5 Device Address 20
See field *190 for entries.
Keypad 5
See field *190 for explanation.
*194
Keypad 6 Device Address 21
See field *190 for entries.
Keypad 6
See field *190 for explanation.
*195
Keypad 7 Device Address 22
See field *190 for entries.
Keypad 7
See field *190 for explanation.
*196
Keypad 8 Device Address 23
See field *190 for entries.
Keypad 8
See field *190 for explanation.
*197
Exit Time Display Interval
0 = no display
1-5 = seconds between display updates
If enabled, keypads display the exit time remaining after arming the
system, with display updates at the interval selected (i.e. if the exit
delay is 30 seconds and “2” is selected in this field, the keypad display
refreshes every 2 seconds, displaying 30, 28, 26, 24, etc.).
An interval greater than “1” may be necessary for some older keypads
to allow users time to enter key presses between display updates.
*198
Display Partition Number
0 = no
1 = yes
If selected, the partition number is displayed in the upper-left corner
of the display. This is useful when using the GOTO partition function.
*199
ECP Fail Display
0 = 3-digt display (“1” + device address)
1 = 2-digit fixed-display as “91”
Select “0” if using Alpha keypads and/or 3-digit Fixed-Word Display
keypads. ECP faults will display “1” plus the device address (00-30) of
device causing the fault (e.g., faults on device 07 display as “107”).
Select “1” if using 2-digit Fixed-Word Display keypads (e.g., certain
6128 series keypads). If selected, ECP faults for all devices will display
as “91” on 2-digit displays, and “191” on 3-digit or Alpha keypads.