FIELD TITLE and DATA ENTRIES EXPLANATION
*86
Cancel Verify
0 = no
1 = yes
When enabled (1 = yes), this feature causes a
CANCELED
ALARM
display on the LCD keypad under the following
conditions:
After the kissoff of the cancel message to the Central Station,
indicating a successful transmission.
When an alarm is successfully canceled before the Central
Station received the Alarm message. E.g., if an alarm is
incorrectly triggered and the user presses code + OFF before
the dial delay time has expired, the message will never go out
to the CS.
When the Cancel report is not enabled and the system is
disarmed:
a.
before
dialer delay expires (alarm report not sent)
message Canceled Alarm is displayed.
b.
after
dialer delay expires message Canceled Alarm is
not displayed
.
*87
Misc. Fault Delay Time
0 = 15 secs 6 = 2-1/2 min #+12 = 8 min
1 = 30 secs 7 = 3 min #+13 = 10 min
2 = 45 secs 8 = 4 min #+14 = 12 min
3 = 60 secs 9 = 5 min #+15 = 15 min
4 = 90 secs #+10 = 6 min
5 = 2 min #+11 = 7 min
Used with zones assigned to a configurable zone type with fault
delay on (configurable zone type digit 6”), and sets a zone
response time of 15 seconds to 15 min. It can be assigned to
zones with sensors that provide a trouble indication when an oil
tank is low, or similar applications for critical condition
monitoring where a non-alarm response is desired.
UL: May only be used on non-burglar alarm and non-fire alarm
zones when used on a fire and/or UL burglar alarm installation.
*88
Program Mode Lockout Options
0 = standard *98 installer code lockout
1 = lockout [
] + [#] reentry after *98 exit (reentry
via installer code only)
2 = not used
3 = lockout all local programming after *98 exit
(reentry via downloader only)
Select the desired options. The following table summarizes the
Program mode lockout options:
Exit *88 Reentry By:
Command Entry Installer Power-upDownloader
*99 n/a yes yes yes
*98 0 no yes yes
*98 1 yes no yes
*98 3 no no yes
pressing [] + [#] within 50 seconds of power up
*89
Event Log Full Report Code
0 = no report
1-F = see description above *59
If an Event Logging selection is made in field 90, a message can be
sent to the central station receiver when the log is 80% full. If the log
becomes full, new messages overwrite the oldest messages in the log.
*90
Event Log Enables
0 = no event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of
entries)
This system has the ability to record various events in a history log
(VISTA-20P = 100 events; VISTA-15P = 50 events). At any time, the
downloader operator can then upload the log and view or print out all
or selected categories of the log. The downloader operator can also
clear the log. Event log can also be viewed at an alpha keypad.
The display/printout at the central station will show the date, time,
event, and description of the occurrences.
Data Entry Example: To select Alarm/Alarm Restore and
Open/Close, enter 9 (1+ 8); to select all events, enter #15.
*91
Option Selection
0 = none
4 = using Audio Alarm Verification (AAV) unit
8 = Enable Exit delay restart/reset ††
U
L
UL installations using the AAV
feature must use the ADEMCO UVCM
module (part of the ADEMCO UVS
system).
Exit Delay Restart/Reset must be disabled.
FOR SIA INSTALLATIONS:
Exit delay
should be enabled.
Multiple choice example: for both AAV and
Exit delay restart, enter # + 12 (4 + 8).
Select the desired options by adding the values of each desired option.
†“Exit Delay Restart/reset option allows use of the [] key to
restart the exit delay at any time when the system is armed STAY or
INSTANT. This feature also enables automatic exit delay reset,
which resets exit delay if the entry/exit door is re-opened before exit
delay time expires after arming AWAY.
IMPORTANT:
AAV should not be used when Paging or Alarm
Reports are sent to a secondary number unless the monitoring zone
option is used (which pauses calls). Otherwise, the call to the
secondary number by the communicator after the alarm report will
prevent the AAV from taking control of the telephone line, and the
AAV Listen in session cannot take place.
4-7