OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR *80, and *81.
Applicable only if Relays andlor Powerline Carrier Devicess are to be used.
*6O OUTPUT DEVICES -
This is an interactive menu mode. Fill in the required data on the worksheet on below and follow
the programming procedure in the installation manual as you enter the data during the displays and prompts that appear
in sequence.
/Votes: 1. For Relays,
field *25 must be programmed for a 4229 (Relays 01 and 02), OR for a 4204 (Relays 01 to 04).
2. For Powerline Carrier devices, field *27 must be programmed with a House Code.
3. Tampers of contacts or expansion units cannot be used to operate devices.
DEVICE
NUMBER
OUTPUT REIAY
OR P.L.C. D.* 01
OUTPUT RELAY
OR P.L.C.DT 02
OUTPUT
RELAY
OR P. L.C. D.* 03
OUTPUT RELAY
OR P.L.C.D7 04
P.L.C. D.* 05
P.LC.DT 06
P.LC.D7 07
P.L.C.D.* 08
I
START
I @either or both*
ZONE
x-lo
ZONE TYPE PART’N
ACTION EVENT LIST SYST OP’N
No.
SELECT
(A) (EV) (ZL) (n) (P)
❑ ❑ ❑ n ❑0 ❑
❑ ❑ ❑
n ❑n ❑
❑ ❑ ❑
n ❑n ❑
❑ ❑ ❑
0 ❑0 ❑
❑ llmnnlmln
STOP
● either or both ●
RESTORE of ZONE TYPE PART’N
ZONE LIST ISYST OP’N
(ZL) (ZT)
R
❑ ❑0 ❑
❑ ❑
n ❑
❑ ❑
n ❑
❑
III ❑
❑
loo ❑
❑
Inn ❑
~‘ p. L.C.D. = Powerline Carrier Device (X-1 O).
Where
X-10 SELECT = Powerline Carrier Device Enter
“1” if Powerline Carrier Device is being used, enter “O if relay is being used.
A = DEVICE ACTION O= No Response;1 = Close for 2 see;2 = Closeand stayclosed;3 = Pulseon and off.
EV = EVENT O= Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
ZL =
ZONE LIST 1, 2, or 3 (from Field *81) or O = Not Used.
“START” ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.
‘STOP RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It
need not be same list as used for START.
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00=
Not Used 06= 24 Hr Silent
01 = Entry/Exit#l
07= 24 Hr Audible
02= Entiy/Exit#2
08= 24 Hr Aux
03= Perimeter
09= Fire Trouble
04= Interior Follower
10= Interior w/Delay
05= Trouble Day/Alarm Night
24= Silent Burglary
Choices for System Operation are:
20=
Armin@tay
38= Chime
21 = Arming-Away 39= Any Fire Alarm
22= Disarming (Code + OFF)
40= Bypassing
31 = End of Exit Time
41 = **AC Power Failure
32= Start of Entry Time
42=
●*System Battety Low
33= Any Burglary Alarm
43= Communication Failure
36= *’At Bell Timeout*’*
*’ Use O
(Any)for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
P = PARTITION No. 1,2, or O for Any
Note: Any zone in “Z7 oin,7 g into akrrm
fault, or trouble WI I actuate relay. ‘
An zone of that type that restores
{WII stoo relav action.
52= KiSSOff
58= Duress
Note:
In normal operation mode:
Code + # + 7 + N Key Entry starts Device N.
Code + # + 8 + N Key Entry stops Device N.
-6-