Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control.
NOTE For UL installations, the system maybe configured as a single partition only.
Field Function
Programmed Values [ ] =
Default Value
SYSTEMSETUP (*2G*30)
*2(3
*21
*22
*23
*24
*25
*27
*28
*29
*3O
INSTALLER CODE
QUICK ARM ENABLE
RF SYSTEM
FORCED BYPASS
RF HOUSE ID CODE
WIRED ZONE EXPANSION
X–10 HOUSE CODE
VOICE MODULE ACCESS CODE
(4285)
OUTPUT TO LONG RANGE RADIO
KEYSWITCH ENABLE (ZONE 7)
ZONE SOUNDS AND TIMING (*3% Y138)
*32
SINGLE ALARM SOUNDING/ZONE
*33
FIRE SOUNDER TIMEOUT
*34 ALARM BELL TIMEOUT
*35 ZONE TYPE 01 ENTRY DELAY
*36 AUDIBLE EXIT WARNING
*37 CONFIRMATION OF ARMING DING
*38
POWER UP IN PREVIOUS STATE
DIALERPROGRAMMING(40+53)
Enter 4 digits, O-9 [4 11 2]
IJJJ_l
[0= no]; 1 = yes Partition
1 t Partition 2 to
[0= none]; 1 = 5800 (5881/5882)
•1
[0= none]; 1 = bypass open zones Partition
1 t Partition 2 to
“O”. for UL installations.
[0][0] Enter 01-31 if using 5827 keypad.
u
Part’n 2 RF House Code= Entered (Part’n 1) Code +1
[0= none]; 1 = 4219; 2 = 4229; 3 = 4204
to
[O= A]; 1= B,2=C,3=D,4 =E,5=F,6=G,7 =H,8=I,9=J,
•1
#10= K,#ll=L, #12= M,#13=N, #14=0, #15=P
(Partition 1 only) 1st digit enter 1-9; 2nd digit enter # + 11 for”*”,
m
or # + 12 for “#”. Default= 00 (no Voice Module).
To enable, enter Trouble code 1–9, B(#+11), C (#+ 12), D (#+ 13),
E (# + 14), or F (# + 15). The 2nd digit of Trouble Dialer Report is
automatically entered from field *60. “O for UL installations.
Enter 1 to enable, [0 to disable].
1 = yes; [0= no]. “O” for UL installations.
to
[0= timeout]; 1 = no timeout.
to I
O = none; [1=4 rein]; 2=8 rein; 3=12 min.
“1” (4 min.) minimum for UL. to
O = O, 1=20 sees, [2=30 sees], Partition 1 t
Partition 2 to
3=45 sees, 4=60 sees; 5=90 sees. “1” max. for UL installations.
Zone Type 02 Entry Delay= Zone Type 01 Delay +30 sees.
Exit Delay = Zone Type 01 Entry Delay + 40 sees.
O= no; [1 = yes]. Partition 1 t
Partition 2 to
[0= no]; 1 = yes. Partition 1 t
Partition 2 to
O= no; [1 = yes]. “1”. for UL installations.
to
In fields *40, *41, *42, enter up to the number of digits shown. Do not fill unused spaces. Enter O-9; #+11 for ‘*’; #+12 for ‘#’;
#+13 for a pause.
*4O
Ml
*42
*43
*45
PABX ACCESS CODE
Enter 4 digits. If fewer than 4 digits are entered, exit by
~
pressing *(and press 41, if entering next field). To clear entries from field,
press @@I.
PRIMARY PHONE
No.
Enter up to 12 digits.
I Ill 1111111
Do not fill unused spaces. If fewer than 12 digits entered, exit by pressing *
(and press 42, if entering next field). To clear entries from field, press* 41 *.
SECONDARY PHONE
No.
Enter up to 12 digits.
I Ill
1111111
Do not fill unused spaces. If fewer than 12 digits entered, exit by pressing *
(and press 43, if entering next field). To clear entries from field, press *42*.
PRIMARY RECEIVER
SECONDARY RECEIVER
PRIMARY SUBS ACCT # (PART’N 1)
~]
*44 SECONDARY SUBS ACCT# (PART’N 1) ~]
PRIMARY RECEIVER
SECONDARY RECEIVER
PRIMARY SUBS ACCT # (PART’N 2)
~] *46 SECONDARY SUBS ACCT # (PART’N 2) ~1
Enter O-9; #+1 1 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F].
Enter * as 4th digit, if 3+1 dialer reporting is to be used. If only 3 digits
t Entry of a number other than one specified
used, exit by pressing * (and press next field).
will give unpredictable results.
To clear entries from field, press *43*,*44*, *45*, or *6*.
Examples:
For Acct No. 1234, enter
l1213i4
For Acct No. B234, enter: #+11121314
For Acct No. 123, enter:
mzmzl