Programming Wired Expansion Zones
Each zone must be programmed into the system using the *56 Zone
Programming mode, which assigns characteristics that define the way the system
responds to faults on that zone. Refer to the Zone Response Type section and
the Zone Programming section for specific instructions on programming wired
expansion zones.
Check-Out Procedure For Wired Expansion Zones
After you have completed installation and programming of all devices, all
expansion zones in each partition of the security system should be checked as
follows:
1. Make certain that all devices and sensors connected to the wired expansion
zones are not in a faulted state. Doors and windows with contacts should be
closed, PIRs should be covered (use a cloth to mask them temporarily if
necessary).
2. Plug in the AC transformer. With all zones intact (including hard-wired zones),
the Alpha keypad connected to the system should display :
DISARMED
READY TO ARM.
If the following is displayed,
DISARMED Press *
to show faults
press the [
*
] key to display the faulted zone(s). Restore any faulted zone(s) as
necessary (also make sure that you have connected a 1000 ohm EOL resistor
across the terminals of unused expansion zones on the 4219 or 4229
module).
When the READY TO ARM message is displayed, you can proceed to the
next step.
3. Fault and restore every contact or sensor in each expansion zone individually
to ensure that it is being monitored by the system. Each time a zone is
faulted, the keypad should display the number of the faulted zone. When each
zone is restored, the READY TO ARM message should appear again.
If some wired expansion zones have been assigned to partition 1 and others
to partition 2, you will need to observe the keypad in the appropriate partition
as each zone in that partition is faulted and restored.
4. When you get the proper displays on the keypad(s), the wired expansion
zones in the system are functioning properly.
5. Unplug the AC transformer.
If a "CHECK 09" message appears on the display, data from the control is not
reaching the zone expander module. Check the wiring and DIP switch settings.