ADEMCO VISTA-20HWse Instrukcja Naprawy Strona 14

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 84
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 13
14–
3. Connect remote Keypads for Partition 1 to terminals 4, 5, 6, and 7 on the
control board, as shown in Figure 6.
4. Connect remote Keypads for Partition 2 to the 4-pin connector on the control
board (see the Summary of Connections diagram for location of the 4-pin
connector for partition 2).
PARTITION 1 KEYPADS
BLACK
RED
GREEN
YELLOW
4
5
6
7
PARTITION 2 KEYPADS
N4632–5
CONNECTOR PINS FOR
PARTITION 2 ON CONTROL BOARD
CONTROL
TERMINALS
KEYPAD CONNECTOR CABLE (SUPPLIED WITH VISTA-20)
Figure 6. Keypad Connections To The Control Board
Mounting the Keypads
1. Make sure addressable type keypads (4137AD, 5137AD, 6128, 6137, 6138,
and 6139) are set to non-addressable mode (address 31), which is the
factory default setting. Refer to the instructions provided with the keypad for
address setting procedure.
2. Mount the keypads at a height that is convenient for the user. Refer to the
instructions provided with the keypad for mounting procedure.
You can either surface mount or flush mount keypads (using an appropriate
Trim Ring Kit: 5137TRK or 6139TRK). Refer to the mounting instructions and
template included with the keypad and/or trim ring kit for specific information.
Using a Supplementary Power Supply to Power Additional Keypads
The control provides 600mA for powering keypads (up to a maximum of 4 per
partition) and other devices from the auxiliary power output. The backup battery
will supply power to these keypads in the event that AC power is lost.
When the control’s auxiliary power load for all devices exceeds 600 mA, you can
power additional keypads from a regulated, 12VDC power supply (e.g., 487–12
supplies 12V, 250mA; 488–12 supplies 12V, 500mA). Use a UL Listed, battery-
backed supply for UL installations.
The 487–12/488–12 power supplies have a backup battery which can power
these keypads in the event of AC power loss.
Keypads powered from supplies which do not have a backup battery will not
function when AC power is lost. Therefore, be sure to power at least one
keypad in each partition from the Control's auxiliary power output.
Connect the additional keypads as shown in Figure 7, using the keypad wire
colors shown. Be sure to observe the current ratings for the power supply used.
Make connections directly to the screw terminals as shown in Figure 7. Make no
connection to the keypad blue wire (if present).
Be sure to connect the negative (–) terminal on the Power Supply unit to
terminal 4 (AUX Ð ) on the control.