SECTION VI
MOUNTING PROCEDURES
- A. MOUNTING THE 4140XM CABINET -
Using two screws, mount the 4140XM cabinet to a wall. If mounting to
sheetrock or concrete, anchors should also be used. wire connections can
now be made to the terminal strips.
- B. MOUNTING THE 4130XM6130XM CONTROLS -
& 413715137 REMOTE CONSOLES
Note that field wiring to these wntrvlsIwnsoles must be completed before the wnttvWwnsoles can be mounted.
TWO METHODS
There are two methods of mounting consoles - Surface Mounting and Flush
Mounting. If a ‘rough-in’ ring (4133) has been installed in the wall in a new
construction application, only the flush mounting method k applicable.
Note
: The four mounting tabs on the right-hand side of the 4133 rough-in
ring must be broken off before flush mounting can be implemented.
SELECTING SITES
Proper selection of mounting location and height is important for optimum
viewabifity of the LCD display on the console. A bcatfon in which lighting k
dire&y above the console should be avoided, since this can shadow the
dkptay. For optimum viewing, the console should also be mounted so that
the display k slightly below eye level to ensure that the system’s users will
look down at the display. For Alpha Console users, refer to the VIEWING
ANGLE ADJUSTMENT paragraph later in this section for instructions for
adjusting theviewing angle of the LCD.
SURFACE MOUNTING 1.
Use the template provided (on a separate sheet) to mark the posltiins on
the wall for the screw mounting holes and the cutout for the interface
wiring. Use wall anchors for the screws and make the cut-out in the wall no
larger than indicated on the template. DO NOT use a Xerox copy of the
tenplate. as it will increase in size by about 1 O?h.
Pull the interface wiring in the wall through the cut-out.
Remove the console’s back cover. The securing screw at the front of the
wnsole must be removed to release the back cover (see Diagram 31 for
scrqw focatiin).
2.
3.
4.
5.
6.
7. See Diagram 31 B for mercantile/industrfal mounting wfth metal cabinet.
Pass the interface wiring through.the opening in the back cover and
through ttre 4143 Expansion Ring (lf used), then mount the back cover
to the wall surface wlth screws. See Diagram 31.
Splice the interface wiring to the console wires (or to the wires on the
interface connector supplied wfth 4137s). A wiring diagram k provided in
the SYSTEM CONFIGURATION (PERIPHERALS) section. Insulated
solderless wire splices (eg. 311) may be used for spfiiing. Check wire
connections carefully before splicing.
Attacf’r the main tidy of the console to the wall-mounted bar& cover. The
console is prop&y attached when ff snaps into pface. Use the securing
screw (previously removed) to secure the console to the back oover (see
Diagram 31 for location of screw hole), then Insert the small name plate
supplied into the recessed opening to cover the screw head (see
Diagram 33).