FUNCTION
ADDRESS
CONFIRMATION OF
I6
ARMING OING
ENABLE
AC POWER LOSS
17
SOUNOING
NOT USED
’18
CONTROL ALARM
19
SOUNDER DISABLE
NOT USED
*2O
DISABLE FIRE
2I
TIME-OUT
FIRE INDICATION
22
AT DISPLAY
COMMENTS: Enter 1 to enable 1/2 second external alarm sounding at the end of exit delay #1 and O to disable
the “ding”,
•1
COMMENTS: Enter 1 to enable this feature. Results in rapid beeping at Control when AC power is lost; otherwise,
enter 0.
Em
MUST BE ZERO
COMMENTS Enter 1 to drs.able the built-in sounder during a burglary, otherwise enter O.
0 MUST BE ZERO
COMMENTS: Disables the sounder time-out feature for any zone designated as a fire zone so that fire sounding
continues until fhe system is reset (required for usage in accordance with UL985, Household Fire). Enter O (time-
out) or 1 (no time-out).
•1
COMMENTS: Enables a display of FIRE (or FI at 41 57) whenever a fire alarm occurs When the alarm is silenced
or times out, the FI display at the 4157 IS replaced by zone number. Enter 1 to enable;, otherwise enter O(only
zone number displayed).