Figure 2.4 Connections to the Accord.
Testing the Installation
Power-up and Initial Test Procedure
When the Accord control panel has been installed in accordance with the preceding
safety and wiring instructions the system should be tested. The test procedure is
outlined below.
Note: Before the test commences all auxiliary devices such as powered sensors
(PIRs), remote keypads, alarm sounders, etc, must be connected.
The Standby battery should not be connected at this point.
19
Group 5  Option 4 Keypad Panic
When enabled (set to 1) this option gives a double-push panic button facility on the
keypad. Both the Ö and # buttons must be held down for two seconds to generate
the panic alarm. The panic condition is indicated by all zone LEDs on the keypad(s)
activating.
Panic Alarms are affected by system option 5.3.1 Engineer Reset for Alarms.
Group 5  Option 5 Keypad Lockout
When enabled (set to 1) this option locks-out the keypad if 20 keys are pressed
without a valid code being entered. This lockout lasts for 10 minutes. Keypad lock-
out is indicated by two illuminated zone LEDs on the keypad scrolling up and down
in opposite directions.
A keypad lockout may be cancelled by operating a zone programmed as keyswitch.
Group 5  Option 6 Bell Output
When set to 0 the Bell output is positive removed (negative applied)  set to 0 by
default.
When set to 1 the Bell output is positive applied (negative removed).
Group 5  Option 7 Trigger Output
When set to 0 the Trigger output defaults to positive removed (negative applied) 
set to 0 by default.
When set to 1 the Trigger output is positive applied (negative removed).
System Programming  Group 9 Factory
Defaults
The control panel programming can be reset to the factory defaults. This is done from
Programming Mode by pressing 981.
If the Engineer or Master User Codes have been lost they can be defaulted separately
from the rest of the system. This is done from Day Mode:
Power down the control.
Re-power the control.
Hold down Ö and # keys together until two beeps are heard.
The Engineer Code is now 9090 and the Master Code is 1234.
Table 3.10 Group 9 System Options.
SNOITPOMETSYS
PUORGNOITPOTLUAFED
9.)seY=1,oN=0(stluafeDyrotcaFteS=8)0(
+
BELL
BELL
TAMP
–R
STRB
+
c
n/c
n/o
+
+
BELL
BELL
TAMP
–R
STRB
+ Supply/Hold-off
Trip/Signal Negative
– Supply/Hold-off
– Tamper return
Strobe – signal
AC
AC
BAT+
BAT–
GND
Primary
AC Mains transformer
Secondary
+
Stand-by Battery
Max 7.2 Ahr
Live
Earth
Neutral
To a.c. mains input
MAINS AND BATTERY CONNECTIONS
+
AUX
LS
TRIG
K'PAD
FULL
SET
PART
SET
NIGHT
SET
TEST ISOLATE
CODE CHIME
ESCAPE LOG EASY SET
123
456
789
0#
ZONES
1
2
3
4
5
6
7
8
TAMPER
DAY
POWER
kpad
+ve
–ve
F1 Battery: 1 A, 20 mm Anti-surge
F2 Keypad/Auxiliary: 500 mA, 20 mm Anti-surge
F3 Bell: 500 mA, 20 mm Anti-surge
Mains Fuse: 100 mA, 20 mm Anti-surge
FUSE RATINGS
CONNECTIONS FOR BELL AND STROBE
CONNECTIONS FOR SAB
KEYPAD AND
LOUDSPEAKER WIRING
ZONE
TAMP
ZONE
1
ZONE
5
ZONE
4
ZONE
3
ZONE
2
ZONE
1
ZONE
8
ZONE
7
ZONE
6
ZONE WIRING
Normaly closed (Open for zone activation)
Przeglądanie stron 15
1 2 ... 11 12 13 14 15 16 17 18 19 20

Komentarze do niniejszej Instrukcji

Brak uwag