Remote Keypad Specification
Connected via a three wire terminal block on the back of the keypad.
Built in piezo warning sounder
Physical Width: 120 mm
Height: 120 mm
Depth: 25 mm
Electrical Voltage Input: 12 V d.c.
Current Drain: 50 mA (typical), 100 mA (maximum)
Appendix B: Connecting a Printer to the System
Installing a Printer
A printer lead (Part no. 2011-096) is required to connect the Accord xpC panel to a
serial printer.
The Printer Lead connects to the control panel using a 3 wire connection:
Yellow wire to LS terminal
Red wire to +Aux(12V)
Black wire to -Aux(0V)
The other end of the lead connects directly to the serial printer via a 25 way D-Type
connector.
The serial printer should have the following settings:
Baud Rate 1200 • Data Bits 8
Parity None • Start Bits 1
Stop Bits 2