- PASSIVE INFRARED MOTION DETECTORS -
GENERAL INFORMATION.
Select a mounting site with the following notes in
mind: Best coverage will be obtained if the
mounting site is selected such that the likely
direction of intruder motion is across the pattern of
protection.
l
Avoid locating the unit where central heating
radiators, flames or heating outlet ducts are
within the protective zones.
POLLING LOOP PIR (4196)
The 4196 is a quad element passive infrared
detector with a built-in RPM that is connected
directly to the 2-wire polling loop.
POLLING LObP PIR (4275)
The 4275 is a dual element passive infrared
detector, with a built-in RPM, that is connected
directly to the 2-wire polling loop.
l
Avoid locating the unit in direct sunlight or
WIRELESS PIR (5775)
directly above strong sources of heat.
The 5775 is a battery operated, wireless, dual
element passive infrared motion detector that can
- Avoid locating the unit on unstable surfaces. be monitored by a 4280 (4280-8) wireless
l
Avoid running alarm wiring close to heavy duty
receiver. The 4280 is connected to the P-wire
electrical cables.
polling loop.
- PHONE LINE INTERFACE -
4171 XT-XM/4171
XM
INSTALLATION
4171 XT-XM14171 XM TERMINALS
The 4171 XT-XM is factory installed in the 4140XM Term. 1: Programmable output (see 1’46) that can
Control. For the 4130XM15130XM Controls, be used as a ground start output with the 675
connect the 4171XT-XM or 4171 XM as shown: Ground Start Module (not UL Listed), as an output to
produce console audible warnings on a remote
sounder (ex: No. 706-12) or as an open/close
trigger for use with other communications media.
l
Only one of the above options can be chosen.
l
If either GROUND START, or CONSOLE AUDIBLE is
used, Aux. Voltage Trigger pin 4 may not be used.
Term. 2: INCOMING PHONE LINE (TIP)
DlwTU c-
1’f14Eno).p0 “*
Term. 3: INCOMING PHONE LINE (RING)
Term. 4: LOCAL HANDSETS (RING)
Term. 5: LOCAL HANDSETS (TIP)
GROUND: Connect green flying lead to a proper
earth ground.
WARNING:
To prevent the risk of shock,
disconnect phone lines at telco jack before
servicing the unit.
- EXTERNAL SOUNDERS -
4140XM
The 4140XM is housed in a metal cabinet and
contains a built-in relay, rated at 2.8 amps. The
output of this relay is a positive (+) trigger from
terminal 8 on TB2, with the negative from TB2-15.
Up to two 702s can be used wired in series; up to
two 719s in parallel.
4130XM15130XM
The 413OXM/513OXM self-contained Controls have
an external sounder output of lOOmA, (negative-
going (-) trigger) from the brown lead. The
continuous. positive (+) is taken from the red/black
lead. From this output you could use up to two 740
High Intensity Sounders, wired in parallel, or one
Amseco Motor Bell, ABBlO31, or up to eight indoor
Piezo Sounders, BRK PAIZOOB in parallel.
4148 RELAY MODULE
(2.8 AMPS @28 VDC)
Other sounders (ex. 702 and 719 self-contained
sirens) can be used with the 4130XM/5130XM, but
the addition of the 4148 Relay Module is necessary
because these sirens (or equivalent) draw more
than the allowable lOOmA of current.
ADVISORY:
Going beyond the above mentioned limits will
overload the auxiliary power and/or relay fuse.
Note that the 5130XM and 4130XM use built-in
solid state fuses (PTCs) that do not need replacing.
The 4140XM uses standard fuses (located on the
terminal strip) which must be ,replaced if blown.