ADEMCO GROUP TECHNICAL SUPPORT KNOWLEDGEBASE
STEP -BY-STEP PROCEDURE
Created: 3.27.2000
Modified: 10.31.2001
File: V10se_23.Doc
Pages: 4
Page 4 of 4
27. The cursor should be flashing under the RC, enter the desired report code
(ex. If 31 enter 3 + 1).
NOTE: In the *58 expert mode you CANNOT enter Hexadecimal values for the
report code, you must use *56.
28. The cursor should be flashing under the IN, Enter the desired input type for this
zone. RF = Supervised RF (3), UR = Unsupervised RF (4), BR = Button Type
RF (5).
29. Press “*” to continue, screen displays “13 INPUT S/N L”
AXXX-XXXX 1
You can also press the “C” key to copy the previous zones serial number.
30. Enter the devices serial number or fault the device to enroll automatically.
31. Press “*” to continue, the cursor should now be flashing under the L. Enter the
devices loop number then press “*” to continue.
32. Screen Displays “XMIT TO CONFIRM PRESS * TO SKIP”. Fault the device
or press “*” to continue.
33. To program another zone repeat steps 25-32
15. To exit *58 expert mode press 00 when the cursor is flashing under the ZN,
screen displays “EXPERT MODE 58”
16. Press “*” + 99 to exit program mode.