ADEMCO Security System VISTA-15CN Instrukcja Użytkownika Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 2
3
Local programming requires the use of a 2-line alpha keypad connected to the
keypad terminals on the control.
Field Function
[ ] = Default Value Programmed Values Field Function
[ ] = Default Value Programmed Values
SYSTEM SETUP (
20
30)
20
INSTALLER CODE
| | |
Enter 4 digits, 09 [4 1 1 2]
21
QUICK ARM ENABLE [0]
1 = enable: 0 = disable
22
RF SYSTEM [0]
0 = none; 1 = 5800 (5881/5882)
4 = 5800 w/ RF Jam Detection
23
FORCED BYPASS [0]
0 = none; 1 = bypass open zones
0 for UL installations.
24
RF HOUSE ID CODE [00]
|
00 = disable all wireless keypad usage;
0131 = using 5827, 5827BD, and 5804BD
25
WIRED ZONE EXPANSION [0]
0 = none; 1 = 4219; 2 = 4229; 3 = 4204
26
CHIME BY ZONE [0]
0 = no; 1 = yes (program zones to chime
on zone list 3)
27
X10 HOUSE CODE
[0]
0 = A, 1 = B, 2 = C, 3 = D, 4 = E, 5 = F,
6 = G, 7 = H, 8 = I, 9 = J, # + 10 = K, # + 11 = L,
# + 12 = M, # + 13 = N, # + 14 = O, # + 15 = P
28
PHONE MODULE ACCESS CODE [00]
|
1st digit: enter 19; 2nd digit: enter # + 11 for
,
or # + 12 for #.
Entering "0" for either digit disables code.
29
OUTPUT TO LONG RANGE RADIO [0]
0 = disable; enable = Trouble code 19, B (# +11),
C (# + 12), D (# + 13), E (# + 14), or F (# + 15).
The 2nd digit of Trouble Dialer Report is
automatically entered from field
60. 0 for UL
installations.
30
HARDWIRE SHORT DETECTION [0]
1 = enable; 0 = disable
ZONE SOUNDS AND TIMING (
31
39)
31
SINGLE ALARM SOUNDING/ZONE [0]
1 = yes; 0 = no; 0 for UL installations.
32
FIRE SOUNDER TIMEOUT [0]
0 = timeout; 1 = no timeout
33
ALARM BELL TIMEOUT [1]
0 = none; 1 = 4 min; 2 = 8 min; 3 = 12 min;
4 = 16 min; 1 (4 min.) minimum for UL.
34
EXIT DELAY (in seconds) [2]
0 = 30 4 = 120
1 = 45 5 = 180
2 = 60 6 = 240
3 = 90
60 sec max for UL installations. Due to the Exit
Delay Restart feature, set for 30 seconds.
35
ENTRY DELAY 1 (zone type 01) [1]
0 = 30; 1 = 45; 2 = 60; 3 = 90; 4 = 120;
5 = 180; 6 = 240. 45 sec max. for UL installations.
36
ENTRY DELAY 2 (zone type 02) [2]
0 = 30; 1 = 45; 2 = 60; 3 = 90; 4 = 120;
5 = 180; 6 = 240. 45 sec max. for UL installations.
37
AUDIBLE EXIT WARNING [1]
0 = no; 1 = yes
38
CONFIRMATION OF ARMING DING [0]
0 = no; 1 = yes (wired keypads and RF);
2 = yes, RF only
39
POWER UP IN PREVIOUS STATE [1]
0 = no; 1 = yes; 1 for UL installations.
Entry of a number other than the one specified will give unpredictable results.
Przeglądanie stron 2
1 2 3 4 5 6 7 8 ... 15 16

Komentarze do niniejszej Instrukcji

Brak uwag