VISTA-10SE PROGRAMMING FORM
Local programming requires the use of a 2-line Alpha keypad (e.g., 6139) connected to the keypad terminals on the control.
To set all program fields to Ademco default values: Key
97.
Field Function Programmed Values [ ] = Default Value
–––––––– –––––––––––––– ––––––––––––––––––––––––––––––––
SYSTEM SETUP (20 27)
20 INSTALLER CODE
[4] [1] [1] [1]
Enter 4 digits, 0-9.
21 QUICK ARM ENABLE
[0]
0 = no; 1 = yes
22 RF SYSTEM TYPE
[0]
0 = none; 1 = 5700 System (4281 type rcvr); 2 = 5800 System (5881/ 5882 type rcvr).
23 FORCED BYPASS FUNCTION
[0]
0 = none; 1 = bypass open zones.
24 RF HOUSE ID CODE
[0][0]
MUST enter (01-31) for 5700 System. Enter also for 5827/5827BD Keypad if used in 5800
system.
25 OUTPUT RELAY MODULE
[0]
0 = none; 3 = 4204.
26 VOICE MODULE ACCESS CODE
[0][0]
1st digit: Enter 1–9; 2nd digit: Enter only #+11 for '', #+12 for '#'.
0 in either position = disabled.
27 OUTPUT TO LONG RANGE RADIO
[0]
0 = no; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field 47) will also be
sent via LRR. All dialer and LRR reports will be in Contact ID format (overriding field 46
selection).
ZONE SOUNDS AND TIMING ( 28 – 39)
28 SINGLE ALARM SOUNDING/ZONE
[0]
0 = no; 1 = yes.
29 FIRE SOUNDER TIMEOUT
[0]
0 = fire sounder timeout; 1 = no fire sounder timeout.
30 ALARM BELL TIMEOUT
[1]
0 = none; 1= 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min.
38 ENTRY DELAY
[2]
0 = 0 sec ; 1= 20 sec; [2 = 30 sec]; 3 = 45 sec; 4 = 60 sec; 5 = 90 sec
EXIT Delay = ENTRY Delay + 15 sec.
39 AUDIBLE EXIT WARNING
[1]
0 = no; 1 = yes.
DIALER PROGRAMMING (40 – 50) Note: In fields 40, 41, & 42: Enter 0–9, # +11 for , # +12 for #, # +13 for a pause.
40 PABX ACCESS CODE
Enter up to 4 digits if PABX code is needed to access an outside line. If fewer than 4 digits
entered, do not fill unused spaces–exit by pressing (and press 41, if entering next field).
To clear entries from field, press 40 .
41 PRIMARY PHONE No.
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing (and press 42,
if entering next field). To clear entries from field, press 41 .
42 SECONDARY PHONE No.
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing (and press 43 if
entering next field). To clear entries from field, press 42 .
43 SUBSCRIBER ACCT No.
Enter 0-9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter
as the
fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as
the first digit of a 4-digit account number for Nos. 0000–0999. End field by pressing
(and press next field).
Examples:
For Acct No. 1234, enter: 1 2 3 4
For Acct No. B234, enter: #+11 2 3 4
For Acct No. 123, enter: 1 2 3
45 PHONE SYSTEM SELECT
[0]
If Cent. Station
IS NOT
on a WATS line: 0 = Pulse Dial; 1 = Tone Dial
If Cent. Station IS on
a WATS line: 2 = Pulse Dial ; 3 = Tone Dial
Entry of a number other than one specified will give unpredictable results.