VISTA-10SE PROGRAMMING FORM
Local programming requires the use of a 2-line Alpha keypad (e.g., 6139) connected to the keypad terminals on the control.
To set all program fields to Ademco default values: Key
✱97.
Field Function Programmed Values [ ] = Default Value
–––––––– –––––––––––––– ––––––––––––––––––––––––––––––––
SYSTEM SETUP (✱20 ✱27)
✱20 INSTALLER CODE
[4] [1] [1] [1]
Enter 4 digits, 0-9.
✱21 QUICK ARM ENABLE
†
[0]
0 = no; 1 = yes
✱22 RF SYSTEM TYPE
[0]
0 = none; 1 = 5700 System (4281 type rcvr); 2 = 5800 System (5881/ 5882 type rcvr).
✱23 FORCED BYPASS FUNCTION
†
[0]
0 = none; 1 = bypass open zones.
✱24 RF HOUSE ID CODE
[0][0]
MUST enter (01-31) for 5700 System. Enter also for 5827/5827BD Keypad if used in 5800
system.
✱25 OUTPUT RELAY MODULE
†
[0]
0 = none; 3 = 4204.
✱26 VOICE MODULE ACCESS CODE
[0][0]
1st digit: Enter 1–9; 2nd digit: Enter only #+11 for '✱', #+12 for '#'.
0 in either position = disabled.
✱27 OUTPUT TO LONG RANGE RADIO
†
[0]
0 = no; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field ✱47) will also be
sent via LRR. All dialer and LRR reports will be in Contact ID format (overriding field ✱ 46
selection).
ZONE SOUNDS AND TIMING (✱ 28 – ✱39)
✱28 SINGLE ALARM SOUNDING/ZONE
†
[0]
0 = no; 1 = yes.
✱29 FIRE SOUNDER TIMEOUT
†
[0]
0 = fire sounder timeout; 1 = no fire sounder timeout.
✱30 ALARM BELL TIMEOUT
†
[1]
0 = none; 1= 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min.
✱38 ENTRY DELAY
†
[2]
0 = 0 sec ; 1= 20 sec; [2 = 30 sec]; 3 = 45 sec; 4 = 60 sec; 5 = 90 sec
EXIT Delay = ENTRY Delay + 15 sec.
✱39 AUDIBLE EXIT WARNING
†
[1]
0 = no; 1 = yes.
DIALER PROGRAMMING (✱40 – ✱50) Note: In fields ✱40, ✱41, & ✱42: Enter 0–9, # +11 for ✱, # +12 for #, # +13 for a pause.
✱40 PABX ACCESS CODE
Enter up to 4 digits if PABX code is needed to access an outside line. If fewer than 4 digits
entered, do not fill unused spaces–exit by pressing ✱ (and press 41, if entering next field).
To clear entries from field, press ✱ 40 ✱.
✱41 PRIMARY PHONE No.
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing ✱ (and press ✱42,
if entering next field). To clear entries from field, press ✱41 ✱.
✱42 SECONDARY PHONE No.
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing ✱ (and press 43 if
entering next field). To clear entries from field, press ✱42 ✱.
✱43 SUBSCRIBER ACCT No.
Enter 0-9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter ✱
as the
fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as
the first digit of a 4-digit account number for Nos. 0000–0999. End field by pressing ✱
(and press next field).
Examples:
For Acct No. 1234, enter: 1 2 3 4
For Acct No. B234, enter: #+11 2 3 4
For Acct No. 123, enter: 1 2 3 ✱
✱45 PHONE SYSTEM SELECT
†
[0]
If Cent. Station
IS NOT
on a WATS line: 0 = Pulse Dial; 1 = Tone Dial
If Cent. Station IS on
a WATS line: 2 = Pulse Dial ; 3 = Tone Dial
†
Entry of a number other than one specified will give unpredictable results.