SERIAL NUMBER
Enter the transmitter’s 7-digit serial number (printed on the transmitter). If an incorrect digit is entered,
press the [#] key to return to prompt (1A).
Note: In order for all parameters to be accepted, you must advance to prompt (1C).
When all 7 digits are entered, press the [*] key. The serial number will be copied into EEROM and the
local memory buffer and “L” will be displayed.
If 30 seconds pass and no entry has been made, the system returns to prompt (1A).
-'
VOICE DESCRIPTOR
0 = Skip to next zone (A)
1 = Enter descriptor mode (existing zone descriptor will be announced, then descriptor 1 will be repeated)
-
d
vv
DESCRIPTOR 1
Enter [#] + 2-digit vocabulary index
number (
vv
) of first descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 2 (descriptor 2 will be announced)
8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
-)
vv
DESCRIPTOR 2
Enter [#] + 2-digit vocabulary index
number (
vv
) of second descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 3 (descriptor 3 will be announced)
8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
-*
vv
DESCRIPTOR 3
Enter [#] + 2-digit vocabulary index
number (
vv
) of third descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 or 8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
See *84 ASSIGN ZONE VOICE DESCRIPTORS section for Vocabulary Index.
*80 DEVICE PROGRAMMING
Use this mode to program Powerline Carrier Devices or zone lists for Chime by Zone feature. Press *80 while in
programming mode.
NOTE:
Entry of a number other than one specified will give unpredictable results.
 
Device Programming
0 = Exit mode, upon which this prompt blinks. Press [*] + any field number to go to that field.
1 = Enter mode
%-
DEVICE NUMBER
Enter the 2-digit device number (01-08) to be programmed
[*] = Continue
00 = Exit Device Programming mode (
displays blinking 80; enter
*
+ desired data field or menu mode number)
b
aa
DEVICE ACTION
Enter the 1-digit action, 0-3, for the device being programmed (current action is displayed).
0 = No response 3 = Pulse on and off
1 = Close for 2 seconds [*] = Continue
2 = Close and stay closed [#] = Return to previous prompt
'
et
START EVENT TYPE
(if applicable)
Enter the 1-digit start event type, 0-3, for the device being programmed.
0 = Not used 3 = Trouble
1 = Alarm [*] = Continue
2 = Fault [#] = Return to previous prompt
d
zl
START ZONE LIST
(if applicable)
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[*] = Continue
[#] = Return to previous prompt
)
zt
START ZONE TYPE
(if applicable)
Enter the 2-digit start zone type for the device being programmed ( see Powerline Carrier Device
Worksheet for zone type/system operation codes later in this manual).
[*] = Continue
[#] = Return to previous prompt
*
zl
STOP ZONE LIST
(if applicable)
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[*] = Continue
[#] = Return to previous prompt