- 15 -
Note:
In normal operation mode:
For Devices 1-6: For Devices 7 and 8: N = device (unit) number
Function + Lights On + N Code + Function + 4 + N (Entry
starts
Device N)
Function + Lights Off + N Code + Function + 7 + N (Entry
stops
Device N)
✱
81 ZONE LISTS FOR OUTPUT DEVICES
Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data
during the displays and prompts that appear in sequence.
Note:
Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may
include
any
or
all
of system's zone numbers.
Zone List 1
: Started or stopped by zone numbers (enter 00 to end entries).
.etc.
[28] [32]
Zone List 2
: Started or stopped by zone numbers (enter 00 to end entries).
.etc.
[29] [33]
Zone List 3
: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)
.etc.
[02] [03]
5800 SERIES LOOP NUMBERS
LOOP
1
5802MN
ENROLL AS "UR" OR "RF"
5806/5807/5808/5808LST
ENROLL AS "RF"
5817
ENROLL AS "RF"
LOOP
1
(PRIMARY)
2
(AUX. CENTER)
3
(AUX. RIGHT)
LOOP
1
(MOTION)
5890/5890PI
ENROLL AS "RF"
5816
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
5816MN
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
5819
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP2
LOOP 3
(TERMINALS)
YOU MUST
ENROLL THIS
BUTTON
LOOP 3
LOOP 1
LOOP 2
LOOP 4
5804
ENROLL
AS "BR"
5804BD
ENROLL AS "BR"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
SET
HOUSE
CODE
YOU MUST
ENROLL THIS
BUTTON
LOOP
1
5809
ENROLL AS "RF"
5801
ENROLL AS "UR" OR "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL THIS
BUTTON
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5818
ENROLL AS "RF"
LOOP
1
5849
ENROLL AS "RF"
LOOP
1
(SOUND)
5814
ENROLL AS "RF"
LOOP1
REED
SWITCH
5802MN2
ENROLL AS "UR" OR "RF"
LOOP
1
5850 (GBD)
ENROLL AS "RF"
(Green)
(Red)
(Yellow)
5819S (WHS & BRS)
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(INTERNAL
SHOCK
SENSOR)
LOOP 3
(TERMINALS)
5816TEMP
ENROLL AS "RF"
LOOP 1
(TERMINALS)
5827BD
PROGRAM HOUSE ID
5827
SET HOUSE ID
LOOP
1
Note:
You must enroll loop 4 on the 5801, 5804 and 5804BD transmitters, regardless of whether it is used or not.
SPECIAL MESSAGES
EE
= DATA ENTRY ERROR (invalid field number entered while programming; re-enter valid field number).
FC
= Communication Failure
EA
= Exit Alarm
CA
= Cancel Alarm
CC
= Modem Communication (system is in communication with the central station)
After powering up,
AC, dI
(disabled) will be displayed after approximately 4 seconds. This will revert to the Real-time Clock in
approximately 1 minute. To bypass this delay, press: [#] + [0].
8
/
The 5802MN, 5802MN2, 5804, 5804BD, 5808LST, 5814, 5816TEMP, 5819, 5819S(WHS & BRS),
5827BD, and 5850(GBD) transmitters are not intended for any UL installations.
Komentarze do niniejszej Instrukcji