LCD display.
A system-wide programmed number of alarm reports for
this zone will be allowed to be transmitted (swinger suppression) in
one armed interval.
Restorals will be sent when the zone is restored
for a time greater than its physical response time (less than 1
second) .
During the disarmed state,
a faulted zone will result in a “DISARMED—
Press * to show faults” display (5137) or a NOT READY display (4137).
Subsequent depression
of the * key will cause all the descriptors
andlor numbers of the faulted zones to te sequentially displayed. No
communicator reports will be initiated.
&pe 3. BURGLARY PERIMETER:
While the System is armed, a faulted zone will
initiate an alarm at the console,
and an external alarm and a latched
LCD display will be present; in addition,
a programmed canmunicator
report will be transmitted. Depression of any key will silence the
Console’s local alarm sounder for 10 seconds. A system-wide programmed
number of alarm reports for this zone will be allowed to be
transmitted (swinger suppression) by the canmunicator in one armed
period. The communicator will transmit a restord message when the
zone is restored for a time greater than its physical response time
(less than 1 second).
During the disarmed state,
a faulted zone will result in a “DlSARMED-
Press * to show faults” display (5137) or a NOT READY display (4137).
Subsequent depression
of the * key will cause all the descriptors
and/or numbers of the faulted zones to be sequentially displayed. No
communicator reports will be initiated.
Type 4. BURGLARY INTERIOR, FOLL(MER:
This zone will always have Exit Delay
#1. The zone has an Entry
Delay if preceded by a fault in an
Entry/Exit zone (type #1 or #2). If not preceded by an Entry/Exit
zone fault, an immediate audible local (console) and external alarm,
latched display,
and a programmed caumunicator report are initiated.
Depressing any key at the Console will silence the Console sounder for
10 seconds.
A system-wide programmed number of alarm reports for
this zone will be allowed to be transmitted (swinger suppression) by
the canmunicator in one armed period.
The canmunicator will transmit a
restoral message when the zone is restored for a time greater than its
physical response time (less than 1 second).
During the disarmed state,
a faulted zone will result in a “DISARMED—
Press * to show faults” display (5137) or a NOT READY (display (4137).
Subsequent depression
of the * key will cause all the descriptors
and/or numbers of the faulted zones to be sequentially displayed.
NO
communicator reports will be initiated.
Type 5.
BURGLARY PERIMETER, TROUBLE BY DAY/ALARM BY NIGNT: During the disarmed
state (day), faulting the zone will initiate a “troublertdisplay and a
latched sounder (beeping).
The console will beep rapidly along with a
latched display of the faulted zone and the word CHECK. Pressing any
key will silence the beeping for 10 seconds. Keying the security code
+ OFF will silence the beeping, but will not clear the display of any
faulted zone until the fault condition is remwed.
Each trouble can restilt in a ‘~troublerlreport (if programmed). A
trouble restoral message will be sent as each zone is restored to
normal condition.
The maximum nunber of trouble reports per armed
period will be limited by the system-wide programmed number of alarm
reports option (swinger suppression).
7