– 47 –
WORKSHEET for SCHEDULES
(installer code + [#] + [6] [4]; master code can only access schedules 01-16 for VISTA-20P, 01-04 for VISTA-15P, and events 00-07 for both
controls; VISTA-15P supports up to 8 schedules, VISTA-20P supports up to 32 schedules )
No. Event Device No. Group No. Partition Start Time/ Stop Time/ Repeat Random
(see list below) for “01” events: for “02” events: for “04-06” events: Days Days (1-4) (yes/no)
enter 01-18 enter 1-8 enter 1, 2, or 3
(VISTA-20P)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events: Master/Installer Installer Only
00 = clear event 03 = latch key report 06 = auto disarm 10 = display custom words 8-10
01 = device on/off 04 = forced STAY arm 07 = display “reminder” 11 = periodic test report
02 = user access 05 = forced AWAY arm
Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week
TABLE OF DEVICE ADDRESSES
This Device Uses Address Reports as †† Enabled By…
RF Receiver 00 100
∗56 zone programming: input device type entry
AUI 1 (touchscreen) 01 n/a
automatic if AUI enable field ∗189 enabled for AUI 1
AUI 2 (touchscreen) 02 n/a
automatic if AUI enable field ∗189 enabled for AUI 2
AUI 3 (touchscreen) (V20P) 05 n/a
automatic if AUI enable field ∗189 enabled for AUI 3
AUI 4 (touchscreen) (V20P) 06 n/a
automatic if AUI enable field ∗189 enabled for AUI 4
Communications Device (LRR) 03 103
automatic if communications device enabled in menu mode ∗29
4286 Voice Module 04 104
automatic if phone module access code field ∗28 enabled
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 (for zones 33 - 40)
module 5 (for zones 41 - 48)
07
08
09
(V20P)
10
(V20P)
11
(V20P)
107
108
109
110
111
∗56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
Relay Modules (4204):
module 1
module 2
module 3
module 4
12
13
14
(V20P)
15
(V20P)
112
113
114
115
∗79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
data field programming as listed below:
always enabled, all sounds enabled.
data field ∗190
data field ∗191
data field ∗192
data field ∗193
data field ∗194
data field ∗195
data field ∗196
RIS Communication 25 n/a
automatic if Remote Interactive Services enabled in field ∗91
5800TM Module 28 n/a automatic
†† Addressable devices are identified by “1” plus the
device address when reporting. Enter report code for
zone 91 to enable device reporting (default = enabled).
See field
∗199 for addressable device (ECP) 3-digit/2-
digit identification keypad display options.
AUI devices are not supervised and therefore do not
report.