m:
Do not exceed the auxiliary total output current limi-
tations described under SPECIFICATIONS.
5(+), 5(-I
Continuous 12V.M: Auxiliary Power for Accessories: Observe
polarjty.
These terminals provide power for accessories such
as space protection devices, e.g. ultrasonic or passive infrared
detectors, photoelectrics,.etc.
The
total
combined current drain from these terminals and the
smoke detector power terminals (3,4) must not exceed 300 MA.
(See SPECIFICATIONS).
7(+). 8(-I
Alarm Roll Voltage:
These terminals provide lLV.BC during an
audible alarm, at a drain of up to 2A. This output is steady
for burglary and audible panic and pulses for fire.
9
10,ll
pTJ:
This output will be produced in both the System Test
and the Fire Test Modes.
Circuit ground Return (-1:
For supplemental use with sorrnder
power.
Power
Input,
18V.AC:
Connect these terminals to the secondary
output terminals of the No. 1323 Transformer.
00 not plug in the transformer yet,.or.connect the battery.
8.
AWITIOWAL CONECTION POSTS (See Oiagram 9)
These posts are provided to permit the connection of accessory devices
(such as the ND. 674 Select-A-Line and the No. 675 Ground Start ,Hodule)
that require special signals.
GROUND START OUTPUT POST:
An output point to provide a mtnnentary
input (until dial tone is obtained) to a No. 675 Ground Start Module
which causes its
relay
to momentarily ground the incoming phone line
for the purpose of obtaining a dial tone outboard of a PBX.
ALTERNATE lElC0 CIIL WfPlll
POST:
An output point that only provides
an alternate line selection request to a No. 674 Select-A-Line if
there is a failure to receive "Kissoff" from the primary telco line
receiver.
If there is a failure to receive *Kissoff" on the first
attempt, this output will request service from the alternate phone
line.
If there is a'failure to receive "Kissoff" on the alternate
phone line, this output will switch back to primary line selection.
If
a No. 659' Telco Line Fault Monitor is used and detects a line
cut, it will override the al ternate line selection described here
and maintain transmission on the intact line.
*Use of this product will Fe&ire usage of a No. 687 Voltage Regulator
to develop the power necessary to operate the b. 659.
628-41