Strona 1 - Installation and Setup Guide

N8026V2 3/10 Rev B 55111100XXMM Control / Communicator Installation and Setup Guide

Strona 2

5110XM Installation and Setup Guide 2-2 5 Slip the bottom part of the circuit board onto the 3 lower Standoffs ensuring it is under the lock washers.

Strona 3 - Non-Compliant UL864 Features

Section 2 – Installing the Control 2-3 5110XM-004-V1+Battery+BatteryWires must berun in ConduitCabinetDoorWired toTransformerFacilityGroundStandoff

Strona 4 - Table of Contents

5110XM Installation and Setup Guide 2-4 Installing the Keypads The following keypads may be used in conjunction with the control panel's LED indi

Strona 5 - List of Figures

Section 2 – Installing the Control 2-5 Installing External Sounders The 5110XM provides one notification appliance circuit output rated 12VDC nominal

Strona 6

5110XM Installation and Setup Guide 2-6 SOUNDER TYPE MANUFACTURER MODEL # SOUNDER TYPE MANUFACTURER MODEL # 2-Wire Wall Mount Horn/Strobe, 12/24V

Strona 7 - General Description

Section 2 – Installing the Control 2-7 342K EOLR BELLHORN +–Alarm polarity shown Figure 2-5: External Sounder Connections Supervising the Notificati

Strona 8

5110XM Installation and Setup Guide 2-8 ALARM765N.O.GROUNDPOLEN.C.NOTES: Use non-polarized indicating devices. Wiring is not supervised. Take care

Strona 9 - Installing the Control

Section 2 – Installing the Control 2-9 supplied. Do not connect to telephone company lines, which provide ground start service. DO NOT connect both

Strona 10 - Back Plate

5110XM Installation and Setup Guide 2-10  Connect closed circuit devices in series in the high (+) side the loop. The 2,000 ohm EOL resistor must b

Strona 11 - 5110XM-004-V1

Section 2 – Installing the Control 2-11 ++2000OHMSEOLRHEATDETECTORHEATDETECTORZONE 5REDEOLPOWERSUPERVISIONRELAYMODULEEOLR-1VIOLET4-WIRE SMOKEOR COMBUS

Strona 13

5110XM Installation and Setup Guide 2-12 Turning Off Fire Alarm Sounding You can turn off Fire alarm sounding by pressing the Silence/Reset key on the

Strona 14

Section 2 – Installing the Control 2-13 Worksheet 3: Auxiliary Relay Output Current Load Total Current Device Model # Device Current X # of Units

Strona 15 - 2K EOLR

5110XM Installation and Setup Guide 2-14 Battery Selection Table Capacity Recommended Battery Comment 7AH Yuasa NP7-12 14AH Yuasa NP7-12 Connect

Strona 16 - Terminal 18

3-1 SECTION 3 Programming  Entering and Exiting Programming Mode Enter Programming mode using eith

Strona 17 - Wiring Devices to Zones 1-5

5110XM Installation and Setup Guide 3-2 Menu Mode Programming The Menu Mode is an interactive mode through which much of the system’s programming is d

Strona 18

4-1 SECTION 4 Data Field Descriptions  About Data Field Programming The following pages list this

Strona 19 - 2_wiresmk-003-V0

5110XM Installation and Setup Guide 4-2 FIELD TITLE and DATA ENTRIES EXPLANATION 0320 Supervisory on Open/Short 0 = trouble on open/supervisory on

Strona 20

Section 4 – Data Field Descriptions 4-3 FIELD TITLE and DATA ENTRIES EXPLANATION 470 Split/Dual Reporting 0 = backup reporting only 1 = alarm, ala

Strona 21

5110XM Installation and Setup Guide 4-4 FIELD TITLE and DATA ENTRIES EXPLANATION 0600 Trouble Report Code Enter the report code for a trouble co

Strona 22 - BATTCONN

Section 4 – Data Field Descriptions 4-5 FIELD TITLE and DATA ENTRIES EXPLANATION 0790 Main/Backup Dialer Enable 0 = disable 1 = enable This field

Strona 23 - Programming

iii UL864 Compliance Requirements  General Information The 5110XM provides features that allow the s

Strona 24

5110XM Installation and Setup Guide 4-6

Strona 25 - Data Field Descriptions

5-1 SECTION 5 Menu Mode Programming  General Information The Menu Mode Programming is an interacti

Strona 26

5110XM Installation and Setup Guide 5-2 PROMPT EXPLANATION Enter Zn Num. (00 = Quit) When all entries to be made for the zone at this time are comple

Strona 27 - 54, 55, 58 – 74)

Section 5 – Menu Mode Programming 5-3 PROMPT EXPLANATION Flashing Cursor (system is ready for entry of word).  ZN 01 A To delete or change the d

Strona 28

5110XM Installation and Setup Guide 5-4 Adding Custom Words You can add up to five installer-defined words to the built-in vocabulary. Each of the fi

Strona 29 - , #12 for #, #13 for a

Section 5 – Menu Mode Programming 5-5 Alpha Vocabulary List (For Entering Zone Descriptors) 000 (Word Space) A 001 AIR 002 ALARM 003 ALCOV

Strona 30

5110XM Installation and Setup Guide 5-6

Strona 31 - Menu Mode Programming

6-1 SECTION 6 System Communication  General Information The process of a successful transmission c

Strona 32 - Field 82 Alpha Programming

5110XM Installation and Setup Guide 6-2

Strona 33

7-1 SECTION 7 Downloading Primer (Remote Downloading is not a UL Listed feature)  General Informat

Strona 34 - Adding Custom Words

5110XM Installation and Setup Guide iv Table of Contents  UL864 Compliance Requirements...

Strona 35 - (For Adding Custom Words)

5110XM Installation and Setup Guide 7-2 Getting On-Line with a Control Panel NOTES:  The Installer must be on premises during a download.  The co

Strona 36

8-1 SECTION 8 System Operation  User Codes This system provides 1 Installer Code and 5 Secondary C

Strona 37 - System Communication

5110XM Installation and Setup Guide 8-2 Keypad Functions The keypad, if used, allows the user to silence alarm and trouble sounders and perform other

Strona 38

9-1 SECTION 9 Testing the System  Fire Walk Test After installation is completed, the 5110XM Syste

Strona 39 - Downloading Primer

5110XM Installation and Setup Guide 9-2 "Check" and "Battery" Displays When the problem has been corrected, the display can be cle

Strona 40

Section 9 – Testing the System 9-3 CONTROL SYMPTOM POSSIBLE CAUSE REMEDY 1. Digital control message not being received. 1a. 5110XM in FIRE WALK TE

Strona 41 - System Operation

5110XM Installation and Setup Guide 9-4

Strona 42 - Keypad Functions

A-1 APPENDIX A Regulatory Agency Statements  The 5110XM may be used as a slave DACT providing centr

Strona 43 - Testing the System

5110XM Installation and Setup Guide A-2 IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS In the event of telephone operational problems, disconnect the

Strona 44 - Troubleshooting

A-3 CANADIAN EMISSIONS STATEMENTS This Class B digital apparatus complies with Canadian ICES-003 NOTICE The Industry Canada Label identifies certifie

Strona 45 - SMOKE DETECTOR

v Table of Contact ID Event Codes ...

Strona 46

5110XM Installation and Setup Guide A-4

Strona 47 - Regulatory Agency Statements

B-1 APPENDIX B Specifications  5110XM Control Physical: 12-1/2" W x 14-1/2" H x 3"

Strona 48

5110XM Installation and Setup Guide B-2

Strona 49

Index-1 Index  "AC LOSS" ...

Strona 50

5110XM Installation and Setup Guide Index-2 K Keypads. ... 2-2 Keypad Connections

Strona 51 - Specifications

WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced wireless security system, it does not offer guaranteed protection aga

Strona 56

5110XM Installation and Setup Guide vi Conventions Used in This Manual  Before you begin using this

Strona 60

5110XM-SIMP-V2ADEMCO 5110XM SIMPLIFIED WIRING DIAGRAMN.O.N.C.2kN.O.N.C.N.O.N.C.2kN.O.N.C.2k2kN.O.N.C.2k129 101113 192017 1815 1614The combined s

Strona 61

ÊN8026V2VŠ N8026V2 3/10 Rev B DOCUMENTATION AND ONLINE SUPPORT For the latest documentation and online support information, please go

Strona 62

1-1 SECTION 1 General Description  About the 5110XM The 5110XM is a fire alarm control/communicator

Strona 63 - (SEE NOTE 6)

5110XM Installation and Setup Guide 1-2 Built-in Indicators and Switches  A built-in warning sounder (Piezo) that provides alarm, supervisory, and t

Strona 64 - ÊN8026V2VŠ

2-1 SECTION 2 Installing the Control  This section describes the procedures for mounting and wirin

Komentarze do niniejszej Instrukcji

Brak uwag