Recommended Programming Procedure
The following is a step-by-step procedure recommended for programming your VISTA-128B
system.
1. Set the keypads (and other peripheral devices) to the appropriate addresses.
2. Set factory defaults by pressing *97.
This will automatically enable keypad addresses 00-01, so be sure at least one keypad is set
to one of these addresses
3. Program system-wide (global) data fields.
Using the programming form as a guide, enter program mode and program all system wide
programming fields. These options affect the entire system, regardless of partitions. They
include control options, downloader and dialer options, RF options, event logging options, etc.
Refer to the COMPLETE LIST OF PROGRAMMING FIELDS for a listing of the program fields
arranged by function.
Note that field 2*00 (number of partitions) must be programmed before continuing.
4. Program partition-specific fields.
When the system-wide fields have been programmed, program all partition-specific
programming fields by first pressing *91 to select a partition (while still in data field program
mode). Then enter the first partition-specific field number *09. The next partition-specific field
will automatically be displayed when you are finished entering the value for field *09. Partition-
specific fields can have different values for each partition. To program the fields for the next
partition, press *91, enter the desired partition number, then enter field *09. Refer to the
MECHANICS OF PROGRAMMING section in the VISTA-128B INSTALLATION
INSTRUCTIONS for detailed instructions.
5. Use #93 Menu Mode for device programming.
Refer to the DEVICE PROGRAMMING section to assign keypad ID numbers and default
partitions for each keypad, and to selectively suppress certain keypad sounding options. Also
use this mode to assign RF receivers, relay modules, the VIP module, the ecp Long Range
Radio, and the Vista Gateway Module.
6. Use #93 Menu Mode for zone programming.
Refer to the ZONE PROGRAMMING section to program zone response types, assign right
loop zones and wireless zones, assign zones to partitions, and to program alarm report codes.
7. Use #93 Menu Mode for programming relays.
Refer to the RELAY PROGRAMMING
section to program desired relay operation.
8. Program Communication options.
Refer to the COMMUNICATION PROGRAMMING section for further instructions to load
communication defaults and to program related fields. Then use #93 mode to program report
codes if necessary.
9. Use #93 Menu Mode for programming alpha descriptors.
Refer to the ALPHA PROGRAMMING section to enter zone and partition descriptors and a
custom installer's message.
10. Use #93 Menu Mode for relay voice descriptors and custom word substitutes.
Refer to the RELAY VOICE DESCRIPTORS section for further instructions for programming
relay descriptors to be annunciated by the VIP module, as well as the CUSTOM INDEX
section for custom word substitutes.
11. Use #80 Mode for programming schedules.
Refer to the SCHEDULING section to program open/close schedules, temporary and holiday
schedules, limitation of access schedules, and time driven events.
12. Define user access codes.
Refer to SECURITY ACCESS CODES section to program authority level, O/C reporting
option, partition assignments, and wireless key assignments for each user.