Dialer Programming
FIELD
TITLE and EXPLANATION
*40
PABX Access Code
Enter the PABX code, if used. To clear entries from field, press 40. If fewer than 6 digits need to be
entered, exit by pressing [], which advances to the next field.
Call Waiting: If the subscriber’s phone service has “call waiting” (and is not using PABX), enter “*70”
(“# + 11”) plus “# + 13” (pause) as the PABX entry to disable “call waiting” during control panel calls. If
the subscriber does not have “call waiting” and is not using PABX, make no entry in this field.
Important: 1. The call waiting disable feature cannot be used on a PABX line. 2. Using Call Waiting
Disable on a non-call waiting line will prevent successful communication to the central station.
VISTA-10PSIA: If call waiting is used, enter call waiting disable digits as described above, and also set
Call Waiting Disable option in field *91.
*41
Primary Phone No.
Enter the primary phone number. If you enter fewer than 20 digits, exit by pressing []. To clear
entries from field, press 41.
NOTE: Backup reporting (8 calls are made to the secondary phone number if no kissoff is received
after 8 attempts to the primary number) is automatic only if there is a secondary number (field 42).
*42
Secondary Phone No.
Enter the secondary phone number. If you enter fewer than 20 digits, exit by pressing []. To clear
entries from field, press 42. See backup reporting note for field 41. Don’t fill unused spaces.
*43
Primary Subs. Acct. No.
Enter the primary subscriber account number. To clear entries from field, press 43.
*44
Secondary Subs. Acct. No.
Enter the secondary subscriber account number. To clear entries from field, press 44.
*47
Phone System Select
Select whether the system will be using pulse or tone dialing, and whether it is on a WATS line.
*48
Report Format (Primary/Secondary)
Select the report format for primary/secondary phone lines from the list on the Programming Guide.
*49
Split/Dual Reporting
Select the desired type of reports to be sent to the primary/secondary numbers. Make selection from the
table in the Programming Guide
. If “0” selected, all reports go only to the primary number unless
unsuccessful, then control will attempt to dial secondary number.
*50
Burglary Dialer Delay
Enter the desired delay time (none, 15, 30, or 45 seconds) before a “BURGLARY ALARM” report is sent
to the central station. This delay allows time for the subscriber to avoid sending a false alarm if the
alarm was inadvertently caused. This delay does not apply to zone type 24 alarms (silent burglary) or
to 24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm), which are always sent
as soon as they occur. UL: must be “0”; SIA Guidelines: delay must be minimum of 30 seconds
VISTA-10PSIA: Delay Time: 1 = 15 secs; 2 = 30 secs; 3 = 45 secs
Delay Disable: 0 = use delay set in entry 1
1 = dial delay disabled for zones listed in zone list 6 (use zone list 6 to enter those zones that
require dial delay to be disabled; these zones ignore the setting in entry 1)
UL: Dial delay plus entry delay must not exceed one minute; use zone list 6 to disable dial delay
from appropriate zones, if necessary.
*53
SESCOA/Radionics Select
Select whether SESCOA format is used.
*54
Dynamic Signaling Delay (Intended for use with Long Range Radio reporting)
Enter the desired time (0-255 seconds in 15-second increments) the panel should wait, per message, for
acknowledgment from the first reporting destination (see 55) before it attempts to send a message to
the second destination. Entering ”0” sends redundant reports to both Primary Dialer and LRR.
UL Installations: For Fire Alarm and UL Burglar Alarm installations without Line Security (Grade A),
the maximum Dynamic Signaling Delay must be no more than 15 seconds.
For UL Burglar Alarm installations with Line Security (Grade AA), Dynamic Signaling Delay must be
“0”. The reports will be sent to both the dialer and the LRR.
4-3
Przeglądanie stron 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 71 72

Komentarze do niniejszej Instrukcji

Brak uwag

Philips 15PF5120/28B manuals

Owner’s manuals and user’s guides for Video Philips 15PF5120/28B.
We providing 1 pdf manuals Philips 15PF5120/28B for download free by document types: User Manual






More products and manuals for Video Philips

Models Document Type
64PP975199 User Manual   Philips 64PP975199 User Manual, 2 pages
39HFL3684S-F7 User Manual   Philips 39HFL3684S-F7 User Manual, 3 pages
MCM240-37B User Manual   Philips MCM240-37B User Manual, 3 pages
Original radio ORD7100R with 30-pin connector for User Manual   Philips Original radio ORD7100R with 30-pin connector for iPod-iPhone FM 10W User Manual, 20 pages
In-Ear Headphones SHE2005PP In-ear White User Manual   Philips In-Ear Headphones SHE2005PP In-ear White User Manual, 2 pages
42PFL7704D-F7 User Manual    Philips 42PFL7704D-F7 Manuel d'utilisation, 1 pages
DVD621AT99 User Manual   Philips DVD621AT99 User Manual, 55 pages
64P9161099 User Manual   Philips 64P9161099 User Manual, 58 pages
42PFL7603D-27 User Manual   Philips 42PFL7603D-27 User Manual, 3 pages
37PF9936-37 User Manual     Philips 37PF9936-37 User Manual, 64 pages
24RF50S99 User Manual   Philips 24RF50S99 User Manual, 4 pages
DVDR3575H-37B User Manual   Philips DVDR3575H-37B User Manual, 3 pages
32PS60B User Manual   Philips 32PS60B User Manual, 4 pages
SWV2432W-27 User Manual   Philips SWV2432W-27 User Manual, 2 pages
SHE3595BK-00 User Manual   Philips SHE3595BK-00 User Manual, 2 pages
SQM4712-27 User Manual     Philips SQM4712-27 User Manual, 24 pages
VR401BMG99 User Manual   Philips VR401BMG99 User Manual, 48 pages
DVP5982-37 User Manual   Philips DVP5982-37 User Manual, 2 pages
23PF5320-28 User Manual   Philips 23PF5320-28 User Manual, 10 pages
HDMI-DVI conversion cable SWV3442W 6 ft User Manual   Philips HDMI-DVI conversion cable SWV3442W 6 ft User Manual, 2 pages