ADEMCO VIA-30PSE PROGRAMMING FORM
FIELD FUNCTION PROGRAMMED VALUES [ ] = Default Value
–––––––– ––––––––––––––– –––––––––––––––––––––––––––––––––
SYSTEM SETUP (*20-*27)
*20 INSTALLER CODE
Enter 4 digits, 0-9...[4] [1] [1] [1]
*21 QUICK ARM ENABLE
†
[0 = no]; 1 = yes
*22 RF SYSTEM TYPE
[0 = none]; 1 = 5700 (4281); 2 = 5800 (5881)
*23 FORCED BYPASS FUNCTION
†
[0 = none]; 1 = bypass open zones
*24 RF HOUSE ID CODE [0][0]
MUST enter (01-31) for 5700 System. Enter also for 5827 Keypad
*25 WIRED EXPANSION/RELAY USED
†
[0 = none]; 1 = 4219; 2 = 4229; 3 = 4204
or 5827BD Keypad.
*26 VOICE MODULE ACCESS CODE
1st digit: Enter 1–9; 2nd digit: Enter only #+11 for '✴', #+12 for '#'.
[0] in either position = disabled.
*27 OUTPUT TO LONG RANGE RADIO
†
[0 = no]; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field
*47) will also be sent via LRR. All dialer and LRR reports will be in Contact
ID format (overriding field *46 selection).
ZONE SOUNDS AND TIMING (*28-*39)
*28 SINGLE ALARM SOUNDING/ZONE
†
[0 = no]; 1 = yes
*29 FIRE SOUNDER TIMEOUT
†
[0 = fire sounder timeout]; 1 = no fire sounder timeout
*30 ALARM BELL TIMEOUT
†
0 = none; [1= 4 min]; 2 = 8 min; 3 = 12 min.; 4 = 16 min.
*38 ENTRY DELAY
†
0 = 0 sec ; 1= 20 sec; [2 = 30 sec]; 3 = 45 sec; 4 = 60 sec; 5 = 90 sec
EXIT Delay = ENTRY Delay + 15 sec
*39 AUDIBLE EXIT WARNING
†
0 = no; [1 = yes]
DIALER PROGRAMMING (*40-*50) In fields *40, *41, *42, enter up to the number of digits shown. Do not fill unused spaces.
Enter 0-9; #+11 for '✴'; #+12 for '#'; #+13 for a pause.
*40 PABX ACCESS CODE
Enter up to 4 digits.
If fewer than 4 digits entered, exit by pressing ✴ (and press 41, if entering next field). To clear entries from field, press ✴40 ✴.
*41 PRIMARY PHONE No.
Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing ✴ (and press 42, if entering next field). To clear entries from field, press ✴41 ✴.
*42 SECONDARY PHONE No.
Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing ✴ (and press 43, if entering next field). To clear entries from field, press ✴42 ✴.
*43 SUBSCRIBER ACCT No.
Enter 0-9; #+11 for B; #+12 for C; #+13 for D;
#+14 for E; [#+15 for F]. Enter ✴ as 4th digit, if 3+1 dialer reporting is to be used.
If only 3 digits used, exit by pressing ✴(and press next field). To clear entries from field, press ✴43 ✴.
Examples:
For Acct No. 1234, enter: 1234
For Acct No. B234, enter: #+11 2 3 4
For Acct No. 123, enter: 1 2 3 ✴
*45 PHONE SYSTEM SELECT
†
If Cent. Sta.
IS NOT
on a WATS line: [0 = Pulse Dial]; 1 = Tone Dial
If Cent. Sta.
IS
on
a WATS line: 2 = Pulse Dial ;3 = Tone Dial
*46 REPORT FORMAT
Also see field *27.
[0 = 3+1, 4+1 ADEMCO L/S STANDARD]
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
*47 SPLIT/DUAL REPORTING [0 = Disable (Backup report only)]
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
1 =Alarms, Restore, Cancel Other Reports
2 =All Reports except Open/Close, Test Open/Close, Test
3 =Alarms, Restore, Cancel All Reports
4 =All Reports except Open/Close, Test All Reports
5 = All Reports (
Dual Reporting)
All Reports
**
A 10-digit code is sent to the pager consisting of
a 4-digit Subscriber #, a 3-digit Event code, & a
3-digit User or Zone #. See Installation
Instructions for an explanation of the 10-
digit code.
TO PRIMARY PHONE No. TO PAGING No.* (SECONDARY)
6 = All reports except Open/Close ** Alarms, Open/Close, Troubles
7 = All reports ** Alarms, Troubles
8 = All reports ** Alarms, Open/Close, Troubles
9 = All reports except Open/Close ** Alarms, Open/Close for Users 5 –
25, Troubles
* Can only be used if Primary reporting is Ademco Contact ID.
†