- 18 -
Zone No. Zone Alarm Report Input Loop Transmitter Vocabulary
(A 01) Type (zt) Code in hex (rc) Type (I) No. (l) Serial Number Index
1|7 | | |
| |
1|8 | | |
| |
1|9 | | |
| |
2|0 | | |
| |
2|1 | | |
| |
2|2 | | |
| |
2|3 | | |
| |
2|4 | | |
| |
2|5
| | |
| |
Button Zones
2|6
| [21] | | [01 00] [5] [3]
| |
2|7
| [22] | | [01 00] [5] [2]
| |
2|8
| [20] | | [01 00] [5] [4]
| |
2|9
| [23] | | [00 00] [5] [1]
| |
3|0
| [21] | | [01 00] [5] [3]
| |
3|1
| [22] | | [01 00] [5] [2]
| |
3|2 | [20] | | [01 00] [5] [4]
| |
3|3
| [23] | | [00 00] [5] [1]
| |
3|4 | | |
| |
3|5 | | |
| |
3|6 | | |
| |
3|7 | | |
| |
3|8
| | |
| |
3|9 | | |
| |
4|0 | | |
| |
4|1
| | |
| |
EXPLANATION OF ZONE ASSIGNMENT TABLE HEADINGS
A 01 = ZONE No.
Zone Numbers are 01 (wired), 2-25 (RF) only, 26-41 (Button) only, 92 (duress), 95, 96, 99 (panic)
zt = ZONE TYPE
00 = Not Used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire without Delay
10 = Interior with Delay
20 = Arm–Stay
21 = Arm–Away
22 = Disarm
23 = No Alarm Response
24 = Silent Burglary
rc = ALARM REPORT CODE
Two Hex Digits. For each Hex Digit, enter: 00–09 for 0–9, 10 for A, 11 for B,12 for C, 13 for
D, 14 for E, 15 for F. If "00" is entered as the first digit, there will be no report for that zone.
For Contact ID reporting, this is enabling code only. Enter any hex digit (other than 00) in the
first pair of boxes. The second pair of boxes is ignored.
i = INPUT TYPE
Enter 3 for RF: Supervised RF
Enter 4 for UR: Unsupervised RF
Enter 5 for BR: Button Type RF
l = LOOP NUMBER
Used with 5800 RF Loop Input Devices. Record transmitter loop number. Entries are 1-4,
depending on device being used. Refer to the transmitter’s instructions for appropriate loop
numbers.
Zones 2-25 should be assigned as Input Type 3 or 4 and
Zones 26-41 should be assigned as Type 5 only.