PROM Oata Group 14
To program,
set Rotary Switch to Position
11
("Not Used") and raise switches
for checked boxes representing bits set within the hexadecimal code.
Ademco Low Speed/SESCOA/Radionics Reporting Codes for Loss of AX. and Alam
Restore*
(Sel,ect from O--)9, B-->F)
q
Loss of A.C.
cl
Alarm Restore
.I
SWITCHES [
*NOTE:
An entry is.mandatory for these two codes (e.g. 9) in the indicated
formats, even if there is no interest in receiving these reports.
CAUTION: Position
12 ('Not
Used')
on the Rotary Switch is .m TO BE
USE0
in
programing the communication PROM.
PRCM Data Group 15
To program, set Rotary Switch to Position 13 ("Not Used") and raise switches
for checked boxes representing bits set within Bhe hexadecimal code;
Ademco Low Spced/SESCOA/Radionics Reporting Codes for Zone Bypass and Bypass
Restore (Select from 0-->g, B-->F)
0.
Zone Bypass
cl
Bypass Restore
t
SWITCHES 1
I1 2 3 4 I 5 6 7 a
I I
I
I
I I I
I
Bit 1Wgtrt 1
2 4 8 1 2 4 a
PROM Data Group 16
To program, set Rotary Switch to Position 14 ("Not Used") and raise switches
for checked boxes representing bits set within the hexadecimal code.
Ademco Low Speed/SESCOA/Radionics Reporting Codes for Test and Low Battery
(Select from 0-->9, B-->F)
cl
Test
0
Low Battery
I
SWITCHES I
I1
2
3
415
6
7
8
I
I
I
I
I
I
I
Bit Weight
1 4 8 1 2 4 8
NOTE:
An entry is mandatory for these two codes (e.g. 9) in the indicated
formats, even if there is no interest in receiving these reports.
628-34
711
Przeglądanie stron 10
1 2 ... 6 7 8 9 10 11 12