Summary of Symphony/Symphony-i LED Operation (Cont'd)
58
LED Operation When Software Download Fails
There are the following sequences providing the extra failure information:
1. CRC failure 1 (calculated CRC does not match CRC provided with binary)
WEB, ARMED, READY and MESSAGE all FAST BLINK for 3 seconds,
following
WEB, ARMED, READY and MESSAGE ON for 3 seconds and following
WEB, ARMED, READY and MESSAGE FAST BLINK for 3 seconds.
2. CRC failure 2 (calculated network CRC does not match CRC provided with
binary)
WEB, ARMED, READY and MESSAGE all FAST BLINK for 3 seconds,
following
WEB, ARMED, READY and MESSAGE SLOW BLINK for 3 seconds and
following
WEB, ARMED, READY and MESSAGE FAST BLINK for 3 seconds.